Tensile properties and integrity of clean room and low-modulus disposable nitrile gloves: a comparison of two dissimilar glove types
-
2012/05/01
Details
-
Personal Author:
-
Description:BACKGROUND: The selection of disposable nitrile exam gloves is complicated by (i) the availability of several types or formulations, (ii) product variability, and (iii) an inability of common quality control tests to detect small holes in the fingers. Differences in polymer formulation (e.g. filler and plasticizer/oil content) and tensile properties are expected to account for much of the observed variability in performance. OBJECTIVES: This study evaluated the tensile properties and integrity (leak failure rates) of two glove choices assumed to contain different amounts of plasticizers/oils. The primary aims were to determine if the tensile properties and integrity differed and if associations existed among these factors. Additional physical and chemical properties were evaluated. METHODS: Six clean room and five low-modulus products were evaluated using the American Society for Testing and Materials Method D412 and a modified water-leak test to detect holes capable of passing a virus or chemical agent. RESULTS: Significant differences in the leak failure rates and tensile properties existed between the two glove types (P = 0.05). The clean room gloves were about three times more likely to have leak failures (chi-square; P = 0.001). No correlation was observed between leak failures and tensile properties. Solvent extract, an indication of added plasticizer/oil, was not associated with leak failures. However, gloves with a maximum modulus <4 MPa or area density (AD) <11 g cm(-2) were about four times less likely to leak. CONCLUSIONS: On average, the low-modulus gloves were a better choice for protection against aqueous chemical or biological penetration. The observed variability between glove products indicated that glove selection cannot rely solely on glove type or manufacturer labeling. Measures of modulus and AD may aid in the selection process, in contrast with common measures of tensile strength and elongation at break. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0003-4878
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:450-457
-
Volume:56
-
Issue:4
-
NIOSHTIC Number:nn:20043393
-
Citation:Ann Occup Hyg 2012 May; 56(4):450-457
-
Contact Point Address:Robert N. Phalen, Department of Health Science and Human Ecology, California State University San Bernardino, 5500 University Parkway, San Bernardino, CA 92407-2397
-
Email:phalen@csusb.edu
-
Federal Fiscal Year:2012
-
Performing Organization:California State University - San Bernardino
-
Peer Reviewed:True
-
Start Date:20090901
-
Source Full Name:Annals of Occupational Hygiene
-
End Date:20120831
-
Collection(s):
-
Main Document Checksum:urn:sha-512:6ea8287ec89b9b3fbabdec68c28d4d2df1af15cab38f422cafbf652c7264e99483a3d3aac9c48833384f7599f6b5b2eb99ece27dc234d35de087f6081a1c16d0
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like