U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Performance-Based Methods

Public Domain


Details

  • Personal Author:
  • Description:
    A recent issue of Analytical Chemistry carried a news article about the introduction of a congressional bill to "accelerate the move toward performance-based analytical methods" for EPA ("Performance Based Methods," Feb. 1, 1996, p. 83 A). We would like to point out that the National Institute for Occupational Safety and Health (NIOSH) has followed the philosophy of developing performance-based methods for monitoring the workplace environment for over 20 years. NIOSH (and the Occupational Safety and Health Administration) methods are evaluated according to a set of criteria. The status of each NIOSH method with respect to those criteria is noted in the NIOSH Manual of Analytical Methods (NMAM, DHHS Pub. #94-113). It should be noted that these methods are only recommendations and their use is not mandated by law. The latest revision of the method evaluation guidelines and criteria is available from NIOSH Publications (4676 Columbia Parkway, Cincinnati, OH 45226) as Guidelines for Air Sampling and Analytical Method Development and Evaluation (DHHS Pub. #95-117). Performance-based methods, as the article states, allow greater flexibility and the opportunity to use newer technology. Along with this flexibility to adapt and modify the methodology comes the responsibility of each laboratory to establish that a method meets the appropriate performance criteria. Usually, the primary criterion is a specified accuracy level, although other factors (such as the limits of detection and quantitation, sample storage stability, etc.) may be just as important. If a laboratory is using a method evaluated by NIOSH, it is reasonable to assume that certain tests, such as sample storage stability, need not be repeated. However, other factors that may be dependent on situations beyond the control of the method, such as changes in the desorption efficiency of a contaminant caused by lot variability of the sampling medium, should be verified by the laboratory doing the analysis. With the performance-based method approach, there can be more than one method for a particular analyte, and methods can be updated without rewriting regulations. The argument that performance-based methods may be more open to legal challenge must be considered in light of the rigorous statistical treatment of the method evaluation data. When the use of a method is mandated by law, the method defines the "true concentration," and in essence, the "true concentration" is that measured by the method. However, all methods have inherent variability and therefore the "true concentration" will also have variability. With the performance-based method approach, this variability in the method result is recognized and is incorporated into the method evaluation criteria. In the case of NIOSH methods, the accuracy criterion states that an acceptable method must produce a result that is within +/-25% of the true concentration 95% of the time with 95% confidence. In the current versions of NMAM and the evaluation guidelines, the accuracy of the method is estimated based on results obtained by defined experiments. This provides the end user with more flexibility in method selection, based on the needs of the monitoring situation. When ensuring compliance with an exposure standard is the goal, use of the most accurate method is desired. The key issue in this instance is to ensure that the worker is not overexposed to the contaminant being monitored and that one's health is not being compromised. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0003-2700
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Volume:
    68
  • Issue:
    15
  • NIOSHTIC Number:
    nn:20034331
  • Citation:
    Anal Chem 1996 Aug; 68(15):A459
  • Federal Fiscal Year:
    1996
  • Peer Reviewed:
    False
  • Source Full Name:
    Analytical Chemistry
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:24630dff72963c7bdf5f867e37a378e675cbe87ab6fc13fdace1dcc7d71737b9b883d475d8d038cf19890aefc6e17daa4b6f9642c4f8af7d897009cb220b0248
  • Download URL:
  • File Type:
    Filetype[PDF - 275.50 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.