Reliability and Validity of Chest Radiograph Surveillance Programs
Public Domain
-
2001/07/01
-
Details
-
Personal Author:
-
Description:Study objectives: Due to the lack of consensus in the literature in the use of posteroanterior (PA) vs PA with right and left oblique views as the optimum radiograph surveillance methodology to investigate pleural changes, a study was undertaken to evaluate the reliability, sensitivity, and specificity of these two approaches. Design: Three experienced radiologist B readers used the 1980 International Labor Office classification system for pneumoconiosis to independently read chest radiographs of workers with individual identifiers masked. All radiographs were read first as a PA view only. Unknown to the B readers, each subject's PA was then matched to his or her corresponding right and left oblique views (film triad) and re-read several weeks later. Setting and participants: The respiratory health of 652 workers exposed to refractory ceramic fiber was assessed as part of cross-sectional and longitudinal surveillance programs. Measurements and results: Statistics for interreader and intrareader reliability between the PA view and film triad methods were calculated. Sensitivity, specificity, and positive predictive value were assessed by comparing the initial cross-sectional study to the longitudinal study. The film triad method had considerably higher interreader reliability ( = 0.59) compared to the PA-only method ( = 0.44). Results from the initial cross-sectional study were then compared to findings evaluated longitudinally. The film triad again was superior, demonstrating a positive predictive value of 73.7% compared to only 47.8% for the PA method. Conclusions: It is our recommendation that the film triad method be used in surveillance studies where both parenchymal and pleural changes are anticipated. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0012-3692
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:64-68
-
Volume:120
-
Issue:1
-
NIOSHTIC Number:nn:20032153
-
Citation:Chest 2001 Jul; 120(1):64-68
-
Contact Point Address:Christina C. Lawson, PhD, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, Mailstop R-15, Cincinnati, OH 45226-1998
-
Email:cjl9@cdc.gov
-
Federal Fiscal Year:2001
-
Peer Reviewed:True
-
Source Full Name:Chest
-
Collection(s):
-
Main Document Checksum:urn:sha-512:5bb6bc517e360c3aed7878bd50fe70cd344ea34d87b0fa21737ecd443e15bafa11def7323fb1820db6d3f29552e440a936945e938dfded4a29c963801ba714a1
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like