Characterization of Plutonium Aerosol Collected During an Accident
Public Domain
-
2004/12/01
-
Details
-
Personal Author:
-
Description:This study determined the plutonium particle size distribution and dissolution rate of 238PuO2 aerosol collected during the 16 March 2000 release of an undetermined amount of 238PuO2 in a room within a plutonium facility at Los Alamos National Laboratory. The facility has been in operation since 1978 to support the development, fabrication, and testing of 238Pu heat sources for the U.S. Department of Energy. Several workers were in the room at the time of the release and in vivo study of five of the workers began the day after the exposure event. Four of the subjects subsequently received chelation therapy. Over 30 fixed air filter samplers (FASs) and four continuous air monitors (CAMs) were operating in the room during the radiological release. One 47-mm-diameter glass fiber FAS filter and one 25-cm-diameter mixed cellulose ester CAM filter containing Pu aerosol from the incident were examined in the study described here. Total alpha radioactivity on the filters was determined by gross alpha counting. Isotopic identification of the 238Pu was made by alpha spectrometry. Film autoradiography was used to characterize the spatial distribution of alpha-emitting particles on the filters. Track-etch autoradiography was used to estimate the distribution of alpha radioactivity in individual plutonium particles on the filters for particle size measurement. The glass fiber filter was then cut into six sections. Particles from two sections were resuspended in alcohol, dispersed as an aerosol using a Lovelace nebulizer, and characterized by aerodynamic diameter using a Lovelace Multi-jet cascade impactor. The measured activity median aerodynamic diameter from the cascade impactor was 4.8 [mu]m with a geometric standard deviation of 1.5. That agreed with the size distribution obtained from the alpha track detection technique. The remaining four filter sections were used in an in vitro dissolution study with synthetic serum ultrafiltrate. The retention of undissolved 238Pu was consistent with a biphasic exponential function. The majority of the 238Pu dissolved with a half-time of 900 d. The information on particle size distribution and solubility from this study was useful in assigning a radiation dose to the exposed workers, supporting the decision to administer chelation therapy, and providing a model for characterizing accident-associated aerosols in the future. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0017-9078
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:87
-
Issue:6
-
NIOSHTIC Number:nn:20031471
-
Citation:Health Phys 2004 Dec; 87(6):596-605
-
CAS Registry Number:
-
Federal Fiscal Year:2005
-
Peer Reviewed:True
-
Source Full Name:Health Physics
-
Collection(s):
-
Main Document Checksum:urn:sha-512:0a7280e13575da0209d56172419c42c462f2f06f73476634a2ae34a57c0bf96885bc1915f69615992fefe07f2fd471318c95f3c28ca32acdbcbd83fb94a06206
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like