A breakthrough time comparison of nitrile and neoprene glove materials produced by different glove manufacturers.
Public Domain
-
1987/11/01
Details
-
Personal Author:
-
Description:The elapsed time between initial contact of a hazardous liquid chemical with the outside surface of protective glove materials and the time at which the chemical could be detected at the inside surface (breakthrough time) was determined for products of different glove manufacturers. Eight nitrile and five neoprene glove products of close to the same nominal thickness were exposed to chemicals. A flow rate of air of 200 cubic centimeters per minute was maintained through the test cell. Breakthrough time was determined using a photoionization detector. The ranges of mean breakthrough times for the eight nitrile products for perchloroethylene (127184) ranged from 30 to 300 minutes (min), indicating large variation in chemical resistance for products carrying the same generic name. Breakthrough times for p-xylene (106423) and n-butyl-acetate (123864) on nitrile gloves also showed variations, as did breakthrough times for the five neoprene products tested with n- butyl-acetate, n-hexane (110543), and ethanol (64175). All but one glove product showed differences between mean measured thickness (21 samples) and nominal thickness, ranging up to 40 percent difference. There was a tendency for degree of resistance to be relatively consistent between glove products for different chemicals tested, although the number of chemicals was small. The authors conclude that there is a significant difference in chemical breakthrough times among generically similar products of different manufacturers, so that substituting a generically equivalent glove for a glove that has been shown to protect the worker may lead to unexpected exposures. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0002-8894
-
Document Type:
-
Genre:
-
CIO:
-
Topic:
-
Location:
-
Volume:48
-
Issue:11
-
NIOSHTIC Number:nn:00180379
-
Citation:Am Ind Hyg Assoc J 1987 Nov; 48(11):941-947
-
CAS Registry Number:
-
Federal Fiscal Year:1988
-
Peer Reviewed:True
-
Source Full Name:American Industrial Hygiene Association Journal
-
Collection(s):
-
Main Document Checksum:urn:sha-512:0449c06b439dcbbe862132dc5ccec3081847f96baf86620ebd1c89ecca882dc4007d466f80be6a2e89a3af100652e30e4e7a19689a7350d0519d9cf8d741a18f
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like