Effect of facial-seal leaks on protection provided by half-mask respirators.
-
1988/05/01
Details
-
Personal Author:
-
Description:The performances of half mask cartridge respirators for protection against aerosols were assessed using a predictive computer model based on quantitative fit test (QNFT) results, type of respiratory filter used, and exposure conditions of work rate of the wearer and size distribution of the exposure aerosol. Conditions were chosen to approximate those encountered in industrial environments. Measurement errors due to loss of particles in facial seal leaks were estimated to be less than 5 percent; change from high efficiency test filters to regular dust, fume, and mist (DFM) filters could significantly reduce protection. Overall protection factors were predicted for 33 industrial aerosol exposures based on assumed QNFT fit factors of 20 and 50; DFM respirators with a fit factor of 50 had predicted protection factors ranging from 21 to 2900 depending on aerosol size distribution. For an unknown aerosol size distribution and average respirator performance, a fit factor of 15 or more was necessary to ensure an overall protection factor of at least 10. For workers exposed to aerosols with mass median aerodynamic diameters greater than 1.0 micron, a fit factor of 11 was required to obtain a protection factor of 10. A protection factor of 50 with DFM filters required a fit factor of greater than 85 for aerosols with mass median aerodynamic diameter greater than 1.0 micron. Recommendations could not be made for disposable dust and mist respirators, but it was estimated that a facial seal leakage below 2 percent was necessary to obtain a protection factor of 5. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0882-8032
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:158-164
-
Volume:3
-
Issue:5
-
NIOSHTIC Number:nn:00180254
-
Citation:Appl Ind Hyg 1988 May; 3(5):158-164
-
Contact Point Address:Environ and Nutritional Scis University of California 405 Hilgard Avenue Los Angeles, Calif 90024
-
Federal Fiscal Year:1988
-
Performing Organization:University of California Los Angeles, Los Angeles, California
-
Peer Reviewed:True
-
Start Date:19830923
-
Source Full Name:Applied Industrial Hygiene
-
End Date:19920831
-
Collection(s):
-
Main Document Checksum:urn:sha-512:33caf7837246e83ba00839c9b45743d92486aafc270607b462fc74236c2996a9f201a7886676afdafa66c13371a909f34fdf88945bc54b102b5ea0ad224f275b
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like