Description:On a winter day in 2008, a male roofer/ foreman died after falling from a telescopic boom lift. He and four other roofing crew members were installing a new roof at a residence undergoing restoration. They had arrived at the job site at approximately 7:45 AM. At approximately 8:00 AM, the foreman and two roofers were installing flashing on the roof of an alcove on the south side of the house while two other roofers were in a pickup truck putting on coveralls. The crew on the roof needed red rosin underlayment (paper) which was in the pickup truck. Using a telescopic boom lift, the foreman, who was not wearing a personal fall arrest system and not tied off, descended to the ground to retrieve the red rosin paper from the pickup truck. He spoke to the two roofers in the truck, retrieved the paper, and returned to the telescopic boom lift. Access to the bucket of the telescopic boom lift was opposite from the control panel. He began his ascent in the telescopic boom lift with the red rosin paper, and was not wearing a personal fall arrest system, nor was he tied off. It is unclear if the access gate to the bucket of the telescopic boom lift was open or closed. When he reached a height of approximately 10 feet, he fell out of the telescopic boom lift platform to the ground. Emergency medical services were immediately contacted. Upon their arrival, an ambulance transported the foreman to the nearest hospital. From there he was transferred to the nearest trauma hospital where he died from his injuries at 3:41 PM. To prevent future occurrences of similar incidents, the following recommendations have been made: Recommendation No. 1: Employers should provide safety training on personal fall protection and have a written safety policy outlining safety practices and procedures, and which state the consequences of not following company policies. Recommendation No. 2: Employers should train employees how to recognize telescopic boom equipment malfunctions and to immediately cease use. Recommendation No. 3: When using mobile equipment, operators should perform walk-around inspections, and check and verify maintenance records before each use. Recommendation No. 4: Employers should instruct employees to cease use of telescopic boom lift equipment if it is involved in an injury until the telescopic boom lift has been thoroughly inspected for malfunctions by qualified personnel.
-
Subjects:
-
Keywords:
- OSHA Region 4
- Accident-analysis
- Accident-potential
- Accident-prevention
- Accidents
- Injuries
- Injury-prevention
- Safety-education
- Safety-equipment
- Safety-practices
- Safety-measures
- Traumatic-injuries
- Work-practices
- Training
- Protective-equipment
- Personal-protective-equipment
- Roofing-industry
- Roofers
- Roofing-and-sheet-metal-work
- Construction-equipment
- Construction-workers
- Construction-industry
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1-8
-
NIOSHTIC Number:nn:20035077
-
NTIS Accession Number:PB2012-114018
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE 08KY007, 2008 Oct ; :1-8
-
Federal Fiscal Year:2009
-
Performing Organization:University of Kentucky
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:2005/07/01
-
End Date:2026/06/30
-
Resource Number:FACE-08KY007
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d9f6ac743eaa415eaa819bc75ce061bd3b9045b245652485e838d9eedf0751a3d841a430be8310d1b0073efdfe73e2d32b5ff522559a2cd9b1d52ec83aafb68e
File Language:
English
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like