Truck Driver Electrocuted in North Carolina [FACE 87-54]
-
1987/07/16
Details:
-
Corporate Authors:
-
Description:A 32 year old truck driver was electrocuted when he raised the bed of the dump truck he was operating, contacting a 12 kilovolt (kV) energized power line. The truck was a 60,000 pound self propelled hydraulic trailer. The worker was attempting to deliver ten loads of lime to a farm supply company. The company for which he worked was small, with no written safety program, relying heavily on the common sense of employees. Part of the lime storage pile had spread under three 12kV power lines running perpendicular to the road in front of the farm supply company. The driver was delivering his second load, having dumped the first load with the truck at about a 45 degree angle to the road. He was standing on the opposite side of the trailer from the power line, with the truck parallel to the line, operating the lever which controlled the bed of the dump truck. The aluminum stop on the bed contacted the power line, electrocuting the worker. The line broke and remained in contact with the truck bed for about 30 minutes before it was deenergized. Farm supply employees attempted unsuccessfully to separate the driver from the truck using broom handles. The victim had a history of accidents and driving while intoxicated. It is recommended that either the storage area for the lime or the power lines themselves be moved to eliminate the hazard, and that the employer begin a safety program which addresses hazards associated with dump truck operations.
-
Content Notes:Publication date provided by the authoring office. There is no publication date indicated on the resource.
-
Subjects:
-
Keywords:
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:2 pages
-
NIOSHTIC Number:00177523
-
NTIS Accession Number:PB88-188685
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, National Institute for Occupational Safety and Health, FACE 87-54, 1987 Jul; :1-4
-
Federal Fiscal Year:1987
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:1987/04/14
-
Resource Number:FACE-87-54
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: