CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i
Steelworker Electrocuted when He Contacts Fan with Damaged Power Cord
-
1988/12/14
Details:
-
Corporate Authors:
-
Description:On September 30, 1988, a 33 year old male steel mill adjuster was electrocuted when he contacted a ventilation fan with a damaged power cord. The facility at which the incident occurred was a steel manufacturing facility employing 534 workers. The adjuster was seen standing on a metal stairway immediately in front of a large, 480 volt ventilation fan, with a startled look on his face; when he was seen in the same position a short time later, another worker deenergized the circuit for the fan. Cardiopulmonary resuscitation was begun immediately, and the victim was transported to a local hospital. The victim was pronounced dead on arrival at the hospital. An inspection following the incident revealed that the power cord of the fan was underneath, and had been damaged by the steel base of the fan. The damaged insulation on the conductors allowed the bare conductors to contact the steel base of the fan, energizing the entire frame. When the electrical system for this part of the steel mill had been installed, a continuous ground connection was not established. The fault current present on the frame of the fan had no path to ground until the victim leaned against the fan and simultaneous contacted the handrails for the metal steps which were at ground potential.
-
Content Notes:Publication date provided by the authoring office. There is no publication date indicated on the resource.
-
Subjects:
-
Keywords:
-
FACE - NIOSH and State:
-
Series:
-
Subseries:
-
DOI:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:3 pages
-
NIOSHTIC Number:00198498
-
NTIS Accession Number:PB91-197616
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, National Institute for Occupational Safety and Health, FACE 89-01, 1988 Dec; :1-4
-
Federal Fiscal Year:1989
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:1988/09/30
-
Resource Number:FACE-89-01
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: