Toward Pillar Design To Prevent Collapse of Room-and-Pillar Mines
Public Domain
-
02/01/2001
Details
-
Description:Three alternative approaches to reduce the risk of catastrophic collapse are described: containment, prevention, and full-extraction. Without good data available on post-failure pillar behavior, containment and full-extraction are the safest.
-