Fundamentals of low-cost aerosol sensor design and operation
-
2024
-
-
Source: Aerosol Sci Technol. 58(1):1-15
Details:
-
Alternative Title:Aerosol Sci Technol
-
Personal Author:
-
Description:Most evaluations of low-cost aerosol sensors have focused on their measurement bias compared to regulatory monitors. Few evaluations have applied fundamental principles of aerosol science to increase our understanding of how such sensors work and could be improved. We examined the Plantower PMS5003 sensor's internal geometry, laser properties, photodiode responses, microprocessor output, flow rates, and response to mono- and poly-disperse aerosols. We developed a physics-based model of particle light scattering within the sensor, which we used to predict counting and sizing efficiency for 0.30 to 10 μm particles. We found that the PMS5003 counts single particle scattering events, acting like an imperfect optical particle counter, rather than a nephelometer. As particle flow is not focused into the core of the laser beam, >99% of particles that flow through the PMS5003 miss the laser, and those that intercept the laser usually miss the focal point and are subsequently undersized, resulting in erroneous size distribution data. Our model predictions of PMS5003 response to varying particle diameters, aerosol compositions, and relative humidity were consistent with laboratory data. Computational fluid dynamics simulations of the PurpleAir monitor housing showed that for wind-speeds less than 3 m s|, fine and coarse particles were representatively aspired to the PMS5003 inlet. Our measurements and models explain why the PurpleAir overstates regulatory PM| in some locations but not others; why the PurpleAir PM| is unresponsive to windblown dust; and why it reports a similar particle size distribution for coarse particles as it does for smoke and ambient background aerosol.
-
Source:
-
Pubmed ID:38993374
-
Pubmed Central ID:PMC11236278
-
Document Type:
-
Funding:
-
Volume:58
-
Issue:1
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type:
Supporting Files
-
gif jpeg gif jpeg gif jpeg gif jpeg xml docx gif jpeg gif jpeg gif jpeg gif jpeg