U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Could HIV-1 RNA Testing be an Option as the Second Step in the HIV Diagnostic Algorithm?

Supporting Files
File Language:
English


Details

  • Alternative Title:
    Sex Transm Dis
  • Personal Author:
  • Description:
    Background:

    There is benefit to early HIV-1 diagnosis and treatment, but there is no Food and Drug Administration–approved quantitative assay with a diagnostic claim. We compared the performance of the Hologic Aptima HIV-1 Quant (APT-Quant) and Aptima HIV-1 Qual (APT-Qual) assays for diagnostic use and the performance of a diagnostic algorithm consisting of Bio-Rad BioPlex 2200 HIV Ag-Ab assay (BPC) followed by APT-Quant (2-test) compared with BPC followed by Geenius HIV-1/2 supplemental assay (Geenius) with reflex to APT-Qual (3-test).

    Methods:

    Five hundred twenty-four plasma, which included 419 longitudinal specimens from HIV-1 seroconverters (78 were after initiating antiretroviral therapy [ART]) and 105 from ART-naive persons with established HIV-1 infections, were used to evaluate APT-Quant performance for diagnostic use. Specimens from 200 HIV-negative persons were used to measure specificity. For the algorithm comparison, BPC-reactive specimens were evaluated with the 2-test or 3-test algorithm. McNemar’s test was used to compare performance.

    Results:

    The APT-Quant detected more samples early in infection compared with APT-Qual. The APT-Quant specificity was 99.8%. Before ART initiation, the algorithms performed similarly among samples from different stages of infection. After ART initiation, the 3-test algorithm performed significantly better (P = 0.0233).

    Conclusions:

    The APT-Quant has excellent performance for diagnostic use. The 2-test algorithm works well in ART-naive samples, but its performance decreases after the IgG response is elicited and with ART-induced suppressed viremia. Providing confirmation and viral load assay with 1 test result could be advantageous for patient care. However, additional factors and challenges associated with the implementation of this 2-test algorithm, such as cost, specimen type, and collection need further evaluation.

  • Subjects:
  • Source:
    Sex Transm Dis. 47(5):S26-S31
  • Pubmed ID:
    31977972
  • Pubmed Central ID:
    PMC11111260
  • Document Type:
  • Funding:
  • Volume:
    47
  • Issue:
    5
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:154448bfc9ffb06bfed73dfdb919f725e2258e19285869d87bac820ef4b0c84c
  • Download URL:
  • File Type:
    Filetype[PDF - 119.04 KB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.