Personal Author:Wesolowski, Laura ; Fowler, William ; Luo, Wei ; Sullivan, Vickie ; Masciotra, Silvina ; Smith, Tara ; Rossetti, Rebecca ; Delaney, Kevin ; Oraka, Emeka ; Chavez, Pollyanna ; Ethridge, Steven ; Switzer, William M. ; Owen, S. Michele
-
Description:Background ; Cepheid’s Xpert HIV‐1 Viral Load (Xpert VL), a simplified, automated, single-use quantitative assay used with the GeneXpert System, is not FDA-approved. ; Objectives ; Using stored plasma, we conducted a study to assess the ability of Xpert VL to quantify viral load relative to the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 (Cobas VL) and to examine the use of the Xpert VL as a qualitative diagnostic test. ; Study Design ; Following HIV-1 viral stock dilutions, we conducted a probit analysis to identify the concentration where 95% of specimens had quantified VLs. We also examined Xpert and Cobas log VL correlation in linearity panels; compared the proportion of 220 seroconverter specimens with virus detected using McNemar’s test; and tested specimens from persons with untreated, established HIV-1 infection (n=149) and uninfected persons (n=497). Furthermore, we examined Xpert VL as a qualitative test in seroconverter specimens with early (n=20) and later (n=68) acute infections. ; Results ; At 1.80 log10 copies/mL, 95% of specimens had quantifiable virus using Xpert VL. Xpert and Cobas VLs were highly correlated (R2=0.994). The proportion of seroconverter specimens with virus detected using Cobas and with Xpert VL was not statistically different (p=0.0578). Xpert VL detected 97.9% of established infections, and specificity was 99.80% (95% CI 98.87%−99.99%). Xpert VL detected 90% and 98.5% of early and later acute infections, respectively. ; Conclusions ; If approved, Xpert VL could allow U.S. laboratories that cannot bring on large, complex testing platforms to conduct HIV monitoring. An approval for diagnostic use may provide timely identification of HIV infections.
-
Subjects:
-
Keywords:
-
Source:J Clin Virol. 122:104214
-
Pubmed ID:31835210
-
Pubmed Central ID:PMC11089535
-
Document Type:
-
Funding:
-
Volume:122
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:1e21c626bd6cd54e522e2e9a26d93d10cd9f094fa3b3fce5cb4f94d5d03044ce
Supporting Files
File Language:
English
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like
COLLECTION
CDC Public Access