Transfusion-related adverse reactions reported to the National Healthcare Safety Network Hemovigilance Module, United States, 2010 to 2012
Supporting Files
-
4 2015
-
File Language:
English
Details
-
Alternative Title:Transfusion
-
Personal Author:
-
Description:BACKGROUND:
In 2010, health care facilities in the United States began voluntary enrollment in the National Healthcare Safety Network (NHSN) Hemovigilance Module. Participants report transfusion practices; red blood cell, platelet (PLT), plasma, and cryoprecipitate units transfused; and transfusion-related adverse reactions and process errors to the Centers for Disease Control and Prevention through a secure, Internet-accessible surveillance application available to transfusing facilities.
STUDY DESIGN AND METHODS:
Facilities submitting at least 1 month of transfused components data and adverse reactions from January 1, 2010, to December 31, 2012, were included in this analysis. Adverse reaction rates for transfused components, stratified by component type and collection and modification methods, were calculated.
RESULTS:
In 2010 to 2012, a total of 77 facilities reported 5136 adverse reactions among 2,144,723 components transfused (239.5/100,000). Allergic (46.8%) and febrile nonhemolytic (36.1%) reactions were most frequent; 7.2% of all reactions were severe or life-threatening and 0.1% were fatal. PLT transfusions (421.7/100,000) had the highest adverse reaction rate.
CONCLUSION:
Adverse transfusion reaction rates from the NHSN Hemovigilance Module in the United States are comparable to early hemovigilance reporting from other countries. Although severe reactions are infrequent, the numbers of transfusion reactions in US hospitals suggest that interventions to prevent these reactions are important for patient safety. Further investigation is needed to understand the apparent increased risk of reactions from apheresis-derived blood components. Comprehensive evaluation, including data validation, is important to continued refinement of the module.
-
Subjects:
-
Source:Transfusion. 55(4):709-718
-
Pubmed ID:25371300
-
Pubmed Central ID:PMC7879051
-
Document Type:
-
Funding:
-
Name as Subject:
-
Place as Subject:
-
Volume:55
-
Issue:4
-
Collection(s):
-
Main Document Checksum:urn:sha256:5a7b40a7c9c2e373dddcdddd7c55d2c4bb06c29e58d45a59066f616f75a38f90
-
Download URL:
-
File Type:
Supporting Files
File Language:
English
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like
COLLECTION
CDC Public Access