High Throughput Determination of Ultra-trace Actinides in Urine by In-line Extraction Chromatography Combined with Quadrupole Inductively Coupled Plasma Mass Spectrometry (EC-ICP-MS)
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

High Throughput Determination of Ultra-trace Actinides in Urine by In-line Extraction Chromatography Combined with Quadrupole Inductively Coupled Plasma Mass Spectrometry (EC-ICP-MS)

Filetype[PDF-566.94 KB]


English

Details:

  • Alternative Title:
    Anal Chem
  • Personal Author:
  • Description:
    Determining actinides in urine is vital for occupational exposure monitoring and radiological emergency response because of the toxicity and radiological dose effects of actinides on human health. Traditional radiochemistry analytical methods used to determine actinide concentrations in urine are time-consuming (sample analysis takes several days) and are hindered by a variety of technical and instrumentation-related obstacles. A high-throughput, fully automated, precise, and accurate in-line method was developed for determining five actinides (|Am, |Pu, |Np, |Th, and |U) at ng/L levels in urine using extraction chromatography combined with quadrupole inductively coupled plasma mass spectrometry (EC-ICP-MS). In this method, the five actinides were successfully separated with the required sensitivity, peak shape, and resolution using a simplified single Eichrom TRU column with a Dionex ICS-5000 system. The separated actinides were subsequently injected into an in-line PerkinElmer (PE) NexION 300D ICP-MS for quantitative determination. The sample-to-sample run time was 23 min for automatic chemical separation and quantification using only 0.5 mL of urine. The limits of detection (LOD) obtained using this method were 0.015, 0.022, 0.039, 4.5, and 2.4 ng/L for |Am, |Pu, |Np, |Th, and |U, respectively. The method routinely had a chemical yield of >84% as well as a linearity (|) coefficient of ≥0.999 for the calibrators. The method proved to be rapid, reliable, and effective for actinide quantification in urine and therefore is appropriate for radiological emergency response incidents.
  • Keywords: