Evaluation of total and inhalable samplers for the collection of carbon nanotube and carbon nanofiber aerosols
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners. As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i

Evaluation of total and inhalable samplers for the collection of carbon nanotube and carbon nanofiber aerosols

Filetype[PDF-1000.48 KB]


English

Details:

  • Alternative Title:
    Aerosol Sci Technol
  • Personal Author:
  • Description:
    A growing number of carbon nanotubes and nanofibers (CNT/F) exposure and epidemiologic studies have utilized 25-mm and 37-mm open-faced cassettes (OFC) to assess the inhalable aerosol fraction. It has been previously established that the 37-mm OFC under-samples particles greater than 20 μm in diameter, but the size-selective characteristics of the 25-mm OFC have not yet been fully evaluated. This article describes an experimental study conducted to determine if the 25- and 37-mm OFCs performed with relative equivalence to a reference inhalable aerosol sampler when challenged with CNT/F particles. Side-by-side paired samples were collected within a small Venturi chamber using a 25-mm styrene OFC, 37-mm styrene OFC, 25-mm aluminum OFC, and Button Inhalable Aerosol Sampler. Three types of CNT/F materials and an Arizona road dust were used as challenge aerosols for the various sampler configurations. Repeated experiments were conducted for each sampler configuration and material. The OFC samplers operated at flow rates of 2 and 5 liters per minute. Results showed that the 25-mm OFC performed comparably to the Button Sampler when challenged with CNT/F aerosols, which was demonstrated in five of the six experimental scenarios with an average error of 20%. Overall, the results of this study indicate that the sampling efficiency of the 25- and 37-mm OFCs adequately followed the ISO/ACGIH/CEN inhalable sampling convention when challenged with CNT/F aerosols. Past exposure and epidemiologic studies that used these OFC samplers can directly compare their results to studies that have used other validated inhalable aerosol samplers.
  • Keywords:
  • Source:
  • Pubmed ID:
    35392279
  • Pubmed Central ID:
    PMC8985588
  • Document Type:
  • Funding:
  • Volume:
    53
  • Issue:
    8
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:

You May Also Like

Checkout today's featured content at stacks.cdc.gov