A fully automated high-throughput liquid chromatography tandem mass spectrometry method for measuring creatinine in urine
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

A fully automated high-throughput liquid chromatography tandem mass spectrometry method for measuring creatinine in urine

Filetype[PDF-675.19 KB]


  • English

  • Details:

    • Alternative Title:
      Clin Mass Spectrom
    • Description:
      Reliable creatinine measurements are important to evaluate kidney function and for creatinine correction to reduce biological variability of other urinary analytes. A high-throughput, accurate liquid chromatography tandem mass spectrometry method for quantitation of human urinary creatinine has been developed and validated. Sample preparation was fully automated including cryovial decapping, sample ID scanning and two serial dilution steps. Quantitation was performed using a stable isotope-labeled internal standard. Multiplexed chromatographic separation of creatinine was achieved within a one-minute analysis and followed by tandem mass spectrometry in positive electrospray ionization mode. The precursor and product ions of creatinine and D|-creatinine were monitored in selected reaction monitoring mode. Method validation results showed reproducibility with within-run precision of 3.59, 3.49 and 2.84% and between-run precision of 4.01, 3.28 and 3.57% for low, medium and high quality control materials prepared from pooled donor urine, respectively. The method showed excellent accuracy with a bias of -1.94%, -0.78% and -1.07% for three levels of certified reference material. The calibration curve was linear throughout a 7.50-300 mg/dL (0.663-26.5 mmol/L) measurement range (R| = 0.999), with the mean slope of 0.0115 (95%CI, 0.0108-0.0122) and intercept of 0.0027 (95%CI, 0.0003-0.0051). The limit of detection (LOD) of the method was 3.17 mg/dL (0.280 mmol/L). Analytical specificity was achieved by chromatographically separating creatinine from potentially interfering creatine within a one-minute run and monitoring the Quantitation Ion/Confirmation Ion (QI/CI) ratios in samples. A simple, accurate, high-throughput method was successfully developed for measuring creatinine in human urine samples.
    • Pubmed ID:
      34414261
    • Pubmed Central ID:
      PMC8372835
    • Document Type:
    • Collection(s):
    • Main Document Checksum:
    • File Type:

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov