Measuring very low air velocities in underground metal/nonmetal mines.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

Filetype[PDF-384.81 KB]


  • English

  • Details:

    • Description:
      "The objective is to accurately measure very low air velocities (0-100 ft/min) in U.S. large-opening underground metal/nonmetal mines. Hundreds of metal/nonmetal underground mines operate throughout the United States. They extract commercial products from deposits such as limestone, salt, and gypsum. Mining generates a wide variety of gases and dusts, such as silica, diesel exhaust, radon, blasting byproducts, and perhaps even methane. If these substances become airborne, they can adversely affect the health and safety of underground workers. Many metal/nonmetal mines have large cross-sectional airways that could be 60 times larger than an average underground coal mine entry. These large airways require adequate volumes of fresh air to dilute, make harmless, and exhaust the toxic and, at times, explosive byproducts. However, in some underground mine sections, air movement is barely perceptible. The technology of measuring very low air velocities will become increasingly more important for operators of large-opening stone mines in order to monitor miner exposure to diesel particulate matter. Conventional anemometers (e.g., vane) are capable of accurately measuring air velocities only above 100 ft/min. Thus, it was necessary to investigate other anemometry technology to detect low air velocities in the range of 0-100 ft/min. Two different portable ultrasonic anemometers were tested. Actual testing was done in an underground limestone mine with openings about 51 ft wide by 29 ft high." - NIOSHTIC-2

      NIOSHTIC no. 20022292

    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +