Using Ultrasonic Anemometers to Evaluate Factors Affecting Face Ventilation Effectiveness
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.
 
 
Help
Clear All
i


Using Ultrasonic Anemometers to Evaluate Factors Affecting Face Ventilation Effectiveness

  • Published Date:

    0/1/1900

Filetype[PDF-759.78 KB]


Details:
  • Description:
    A test system was developed for measuring airflow in the National Institute for Occupational Safety and Health (NIOSH) ventilation gallery using a three-axis ultrasonic anemometer. The gallery was used to simulate face airflow conditions in underground mines having a blowing curtain. Airflow data collected at multiple sampling locations between the face and the end of the curtain were used to draw airflow profiles for different curtain setback distances, intake flow quantities and entry widths. In addition, methane was released at the face, measured at the sampling locations, and displayed as methane distribution in the area between the curtain and the face. Entry geometry had a significant effect on airflow patterns, and the flow patterns affected the distribution of methane in the entry. Flow measured at and parallel to the face was a good predictor of methane dilution and removal within two feet of the face.