FLAC Simulation Of Split-Pipe Tests On An Instrumented Cable Bolt
  • Published Date:
    0/1/1900
Filetype[PDF - 687.24 KB]


Details:
  • Description:
    A new instrumented cable bolt has been developed by the National Institute for Occupational Safety and Health at the Spokane Research Laboratory in Spokane, WA. Although various instruments are available to measure load distribution and magnitude along a grouted cable, this instrument is innovative in that it uses strain gauges internal to the cable as load-measuring sensors. The instrument has been successfully tested in the field at FMC s Granger Mine, Meikle Mine, and Getchell Mine. A split-pipe laboratory pull test was performed on each of three cable bolts instrumented with the new device. Each test consisted of grouting a 1.83-m-long cable in two 0.91-m-long sections of schedule 80 pipe. A numerical analysis was then performed in which laboratory boundary conditions were simulated and model properties derived from textbook guidelines. The loads calculated by the model were then compared to the measured loads.