An Assessment Of Engineering Noise Controls At A Talc Processing Plant
  • Published Date:
    0/1/1900
Filetype[PDF-799.56 KB]


Details:
  • Description:
    National Institute for Occupational Safety and Health (NIOSH) researchers conducted an investigation to quantify sound levels and to determine the amount of sound reduction provided by engineering noise controls installed in a talc processing plant. Baseline sound level and sound intensity measurements were performed at the plant and the measurement locations were recorded for comparison to post-control measurements. Follow-up measurements were then made at the same locations after the initial noise controls were installed. The plant subsequently decided to implement additional noise controls and the researchers returned to conduct measurements for a final analysis of all noise controls. The most significant results showed a sound level reduction in the main mill area from a range of 93-104 dB(A) down to 90-94 dB(A), and a total sound power level reduction of 21 dB(A) for air classifying mill 3.

  • Supporting Files:
    No Additional Files
No Related Documents.