Instrumented Handles For Studying Hand-Transmitted Vibration Exposure - Introduction; Proceedings Of The First American Conference On Human Vibration
-
2006
-
Source: Proceedings of the first American conference on human vibration, June 5-7, 2006, Morgantown, West Virginia. Dong R, Krajnak K, Wirth O, Wu J, eds. Morgantown: WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2006-140, 2006 Jun; :140-141
Details:
-
Personal Author:
-
Corporate Authors:
-
Conference Authors:
-
Description:Instrumented handles or dynamometers are widely used to measure hand forces and/or the biodynamic response of hand-arm system. To study hand-transmitted vibration exposure, six generations of instrument handles were constructed or initially developed by researchers in ECTB/HELD/NIOSH. This presentation provided a summary of these handles. Their basic characteristics, limitations, and usefulness are described, which may help their appropriate applications and further improvements. Six Designs of Instrumented Handles Handle 1: The conceptual design is recommended in ISO 10819 (1996)1 for glove test. The grip force is measured by detecting bending strains on a measuring beam in the handle. A special handle fixture was designed to connect the handle to a shaker. Except the screws, the handle and fixture were made from aluminum. Handle 2: The design is based on the principle of shear strain measurement.2-3 Both grip and push forces can be measured simultaneously using this handle. This handle was directly designed for a simulated vibrating tool. Handle 3: This design is basically composed of a handle base, a measuring cap, and two charge-based sensors (Kistler 9212) sandwiched between the base and cap. The handle was also made from aluminum. The fixture for Handle 1 was also used with this handle. This generation of handle has three different handle diameters (30, 40, and 50mm).4 Handle 4: This design is an improvement from Handle 3. The handle fixture was totally redesigned and it was much stiffer than the previous one. The aluminum measuring cap was replaced with a magnesium cap. Handle 5: The basic structure of this handle is the same as that for Handle 3. However, the piezoelectric sensors were replaced with two strain gage based sensors (Interface SML-50). Handle 6: This handle includes two measuring caps, four piezoelectric sensors, and a handle centre base. The handle fixture was the same as that with Handle 4. Methods for Handle Examinations The static and dynamic characterizations were performed using the methods reported by Dong et al.5-6 Results and Discussion Handle 1: The static force measurement depended on the hand grip location on the handle. Its natural frequency was less than 200 Hz.5,6 Because the transmissibility of gloves may not vary significantly with the applied grip force, this handle may be acceptable for glove test. However, the force measurements with this handle may not be reliable. Handle 2: The static force measured with this handle was insensitive to the hand acting location. However, when the handle was vibrating, the force signals could be totally distorted. For this reason, it was not used for vibration studies.
-
Subjects:
-
Source:
-
Document Type:
-
Genre:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: