Welcome to CDC Stacks | Head-Trunk Motion Increase With Arm-Rest Controls - Introduction; Proceedings Of The First American Conference On Human Vibration - 8445 | National Institute for Occupational Safety and Health
Stacks Logo
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.
 
 
Help
Clear All Simple Search
Advanced Search
Head-Trunk Motion Increase With Arm-Rest Controls - Introduction; Proceedings Of The First American Conference On Human Vibration
  • Published Date:
    6/1/2006
Filetype[PDF - 197.08 KB]


Details:
  • Description:
    Heavy equipment manufacturers have made a long-term commitment to minimize operator vibration exposure for comfort, performance, and health reasons. Domestic and international guidelines/standards and EC laws dictate exposure limits based on measurement of vibration at the interface between the seat and the operator s buttocks using seat-pad accelerometry.1-4 This is historically based on the assumption that the only major source of vibration is transmitted through the seat pan. However, vibration may also be imparted to the head and neck via the steering wheel and/or arm-rest controls and a relatively rigid upper body.5 Unfortunately, little is known regarding the influence of arm position on head and neck motion. The purpose of this study was to investigate relative head and trunk motions during riding simulations of large construction equipment, using three different arm control options. Methods Five typical heavy equipment ride files were played back through a man-rated Servo Test 6-degree-of-freedom vibration system. An 8-camera Vicon motion capture system operating at 200 frames per second, recorded the motion of reflective surface markers on 5th, 50th, and 95th percentile right-handed male subjects, using 3 seat and control configurations (steering wheel (SW), floor mounted armrest controls (FM), seat-mounted armrest controls (SM)). Two trials were performed for each ride and seat control combination (each trial: 60 sec of 6-dof and 60 sec of vertical vibration). The relative motions (change in distances) from the marker over the xiphoid process (caudal end of sternum) to markers over each shoulder, each mid-clavicle, the presternal notch, and to each of four markers on a tight band around the head were calculated (12,001 frames, 6-dof motion only). As a rigid body control, distances between markers on the head band were also monitored. The standard deviation (SD) of the 12,001 distances between pairs of markers was normalized by the mean (L) of the associated distances producing: SD/L which was used as a measure of motion. Error assessments were also performed by analyzing the motion between relatively fixed markers (on the headband). A repeated measures analysis of variance was used to evaluate the results. While five ride files were used, only one ride file containing significant lateral acceleration components was analyzed for comparing the effects of two armrest controls versus use of a steering wheel for this part of our study. Results Values of SD/L between the points on the relatively rigid head band were consistently small and similar to each other for all conditions with one exception due to treatment (SM v SW, p=0.0145). SD/L between the markers over the xiphoid process and the presternal notch, another region that should be relatively rigid, were also similar to each other for all conditions. Use of floor-mounted, arm rest controls versus a steering wheel produced a significant increase in the value of SD/L between the xiphoid process and: the right shoulder marker (92%, p=0.0316), the right mid-clavicle marker (47%, p=0.0478), and the right-front marker on the head band (28%, p=0.0182). Use of floor-mounted, arm rest controls versus seat-mounted, arm rest controls

  • Supporting Files:
    No Additional Files