U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Assessments And Refinements Of An Anthropodynamic Manikin For Seating Dynamics Applications - Introduction; Proceedings Of The First American Conference On Human Vibration

Public Domain
File Language:
English


Details

  • Personal Author:
  • Description:
    The current laboratory methods for assessing the vibration attenuation performance of seats involve repetitive trials with a number of human occupants, and raise certain ethical concerns. Moreover, the measurements with human subjects yield considerable variability in the data. Alternatively, several anthropodynamic manikins have been developed for effective assessments of the coupled seat occupant system [1]. The effectiveness of a manikin in predicting the response of a coupled seat-occupant system lies in its ability to reproduce the biodynamic response of the seated human body in terms of force-motion relationship at the body-seat interface, such as apparent mass (APMS). A number of prototype manikins have thus been developed on the basis of biodynamic characteristics of vertical vibration-exposed seated occupants of different body masses in the vicinity of 5th, 50th and 95th percentile male population. This study concerns with the analysis of a passive prototype manikin to enhance its ability to reproduce the idealized APMS response characteristics of the vibration-exposed seated human subjects defined in ISO-5982[2] for mean body masses of 55, 75 and 98 kg. Methods The APMS responses of a prototype anthropodynamic passive manikin were thoroughly characterized in the laboratory under different excitations and body mass configurations. The manikin was designed with sufficient flexibility to configure mechanical-equivalent models corresponding to seated body masses of 55, 75 and 98 kg, by adding/removing specified masses and springs (Fig. 1). The manikin, configured for a specific body mass, was positioned on a rigid seat without a backrest, which was fixed to the force platform of a whole-body vertical vibration simulator. The simulator was programmed to synthesize random vertical vibration with flat acceleration power spectrum in the 0.4-20 Hz frequency range with two different magnitudes: 1 and 2 m/s2 overall rms acceleration. The total static and dynamic forces of the manikin to and the seat were measured using the force platform, while a single axis accelerometer was installed on the seat pan to measure acceleration due to vertical excitation. The measured data was appropriately corrected for the rigid seat inertia force, and the apparent mass [ ]
  • Subjects:
  • Document Type:
  • CIO:
  • NIOSHTIC Number:
    nn:na
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:40b436f9aa960a7720cdef9cc75386adae10b1fd48214a01d60fcf05cbab8d3c6133da897ce4b0301ee419c5eaa59177614fc33d9305bcf460435c9f41ae6394
  • Download URL:
  • File Type:
    Filetype[PDF - 179.69 KB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.