Portable refuge alternatives temperature and humidity tests
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Portable refuge alternatives temperature and humidity tests

Filetype[PDF-1.42 MB]


  • English

  • Details:

    • Alternative Title:
      Min Eng
    • Description:
      Federal regulations require refuge alternatives in underground coal mines to sustain life for 96 h while maintaining an apparent temperature below 35 °C (95 °F). Research by the U.S. National Institute for Occupational Safety and Health (NIOSH) has shown that heat and humidity buildup is a major concern with refuge alternatives because they have limited ability to dissipate heat, and high internal air temperature and relative humidity (RH) may expose occupants to heat stress. The heat transfer process within and surrounding a refuge alternative is complex and not easily defined, analytically or experimentally. To investigate heat and humidity buildup in refuge alternatives, NIOSH conducted multiple in-mine, 96-h tests on a 10-person tent-type refuge alternative, a 23-person tent-type refuge alternative and a six-person metal-type refuge alternative. The results show that when moisture was introduced to represent perspiration and respiration from miners (wet tests), the average temperature at midheight increased by 10.5 °C (18.9 °F) and the RH approached 88 percent for the 10-person tent-type refuge alternative; the average temperature at midheight increased by 9.4 °C (16.9 °F) and the RH approached 94 percent for the 23-person tent-type refuge alternative; and the average temperature at midheight increased by 7.7 °C (13.9 °F) and the RH approached 95 percent for the six-person metal-type refuge alternative. For the dry tests, where no moisture was introduced, the average internal temperature increased by 12.6 °C (22.7 °F) for the 10-person tent-type refuge alternative, by 10.3 °C (18.5 °F) for the 23-person tent-type refuge alternative and by 8.4 °C (15.1 °F) for the six-person metal-type refuge alternative. These results may provide refuge alternative manufacturers and mine operators with guidelines and considerations for evaluating temperature profiles for portable refuge alternatives. The information may then be used to make decisions on occupancy ratings and heat mitigation strategies based on the thermal environment in which the refuge alternatives will be installed.
    • Subject:
    • Pubmed ID:
      30686842
    • Pubmed Central ID:
      PMC6345178
    • Document Type:
    • Collection(s):
    • Main Document Checksum:
    • File Type:

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov