i
Implementation Lessons Learned From the Benefits of Enhanced Terminal Room (BETR) Disinfection Study: Process and Perceptions of Enhanced Disinfection with Ultraviolet Disinfection Devices
-
January 14 2018
-
Source: Infect Control Hosp Epidemiol. 39(2):157-163
Details:
-
Alternative Title:Infect Control Hosp Epidemiol
-
Corporate Authors:
-
Description:OBJECTIVE
To summarize and discuss logistic and administrative challenges we encountered during the Benefits of Enhanced Terminal Room (BETR) Disinfection Study and lessons learned that are pertinent to future utilization of ultraviolet (UV) disinfection devices in other hospitals.
DESIGN
Multicenter cluster randomized trial.
SETTING AND PARTICIPANTS
Nine hospitals in the southeastern United States.
METHODS
All participating hospitals developed systems to implement 4 different strategies for terminal room disinfection. We measured compliance with disinfection strategy, barriers to implementation, and perceptions from nurse managers and environmental services (EVS) supervisors throughout the 28-month trial.
RESULTS
Implementation of enhanced terminal disinfection with UV disinfection devices provides unique challenges, including time pressures from bed control personnel, efficient room identification, negative perceptions from nurse managers, and discharge volume. In the course of the BETR Disinfection Study, we utilized several strategies to overcome these barriers: (1) establishing safety as the priority; (2) improving communication between EVS, bed control, and hospital administration; (3) ensuring availability of necessary resources; and (4) tracking and providing feedback on compliance. Using these strategies, we deployed ultraviolet (UV) disinfection devices in 16,220 (88%) of 18,411 eligible rooms during our trial (median per hospital, 89%; IQR, 86%–92%).
CONCLUSIONS
Implementation of enhanced terminal room disinfection strategies using UV devices requires recognition and mitigation of 2 key barriers: (1) timely and accurate identification of rooms that would benefit from enhanced terminal disinfection and (2) overcoming time constraints to allow EVS cleaning staff sufficient time to properly employ enhanced terminal disinfection methods.
TRIAL REGISTRATION
Clinical trials identifier: NCT01579370
-
Subjects:
-
Source:
-
Pubmed ID:29331170
-