Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Electromagnetic interference from personal dust monitors and other electronic devices with proximity detection systems

Filetype[PDF-1.54 MB]


  • English

  • Details:

    • Alternative Title:
      Min Eng
    • Description:
      In April 2016, the U.S. Mine Safety and Health Administration (MSHA) began requiring the use of continuous personal dust monitors to monitor and measure respirable mine dust exposures to underground coal miners. Mines are currently using the PDM3700 personal dust monitor to comply with this regulation. After the PDM3700's implementation, mine operators discovered that it interfered with proximity detection systems, thus exposing miners to potential striking and pinning hazards from continuous mining machines. Besides the PDM3700, other electronic devices were also previously reported to interfere with proximity detection systems. MSHA sought the aid of the U.S. National Institute for Occupational Safety and Health (NIOSH) and mining industry stakeholders to determine how the PDM3700 and some other electronic devices and proximity detection systems interact with each other. Accordingly, NIOSH investigated existing standards, developed test protocols, designed experiments and conducted laboratory evaluations. Some interferences were observed to be caused by electromagnetic interference from some electronic devices, including the PDM3700. Results showed that there was no significant interference when the PDM3700, as well as other electronic devices, and the miner-wearable component of the proximity detection system were separated by distances of 15 cm (6 in.) or greater. In the present study, it was found that the PDM3700 and the personal alarm device needed to be at least 15 cm (6 in.) apart in order for them to be used simultaneously and reduce potential interference.
    • Subjects:
    • Pubmed ID:
      30147149
    • Pubmed Central ID:
      PMC6108086
    • Document Type:
    • Collection(s):
    • Main Document Checksum:
    • File Type:

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov