CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i
Comparing plasma, serum and whole blood indium concentrations from workers at an indium-tin oxide (ITO) production facility
-
Jul 25 2016
-
-
Source: Occup Environ Med. 73(12):864-867.
Details:
-
Alternative Title:Occup Environ Med
-
Personal Author:
-
Description:Objective
Occupational exposure to indium compounds including indium-tin oxide (ITO) can result in potentially fatal indium lung disease. We compared plasma, serum and whole blood indium concentrations (InP, InS and InB) from workers at a single ITO production facility to assess the comparability of these matrices used for biological monitoring of indium exposure.
Method
InP, InS and InB were measured using inductively coupled mass spectrometry from consenting workers at an ITO production facility with specimen collection occurring during June–July 2014. Matched pairs from workers were assessed to determine the matrix relationships using the Pearson correlation, paired t-tests, per cent difference, linear regression and κ statistics.
Results
Indium matrices were collected from 80 workers. Mean (SD) InP, InS and InB were 3.48 (3.84), 3.90 (4.15) and 4.66 (5.32) mcg/L, respectively. The InS–InP difference was 14%; InS was higher in all but two workers. InP and InS were highly correlated (r=>0.99). The InB–InS difference was 19%; InB was higher in 85% of workers. The InB–InP difference was 34%; InB was higher in 66% of workers. InB was highly correlated with both InP and InS (r=0.97 and 0.96, respectively). κ Statistics were 0.84, 0.83 and 0.82 for InP, InS and InB, respectively, for individuals with each matrix ≥1 mcg/L (p<0.01).
Conclusions
While all matrices were highly correlated, we encourage the use of InP and InS to reliably compare studies across different populations using different matrices. The higher per cent difference and increased variability of InB may limit its utility in comparisons with InP and InS in different populations.
-
Subjects:
-
Source:
-
Pubmed ID:27456157
-
Pubmed Central ID:PMC5822678
-
Document Type:
-
Funding:
-
Name as Subject:
-
Place as Subject:
-
Volume:73
-
Issue:12
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: