Air sampling filtration media: Collection efficiency for respirable size-selective sampling
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Air sampling filtration media: Collection efficiency for respirable size-selective sampling

Filetype[PDF-1.10 MB]


  • English

  • Details:

    • Alternative Title:
      Aerosol Sci Technol
    • Description:
      The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 |m pore sizes), polycarbonate (0.4, 0.8, 2, and 5 |m pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 |m pore sizes), polyvinyl chloride (PVC; 0.8 and 5 |m pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 |m pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10-400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min|. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes.
    • Subject:
    • Pubmed ID:
      26834310
    • Pubmed Central ID: