A comparison of clinical laboratory data for assigning a consensus value for manganese in a caprine blood reference material
Supporting Files
-
10 2012
-
File Language:
English
Details
-
Alternative Title:J Anal At Spectrom
-
Personal Author:
-
Description:Biomonitoring for manganese (Mn) exposure is important due to its potential to cause adverse health effects. In this study, we investigate how different sample preparation methods (simple dilution, digestion, volumetric, gravimetric), calibration protocols (aqueous, blood-based, standard additions), and instrumental techniques affect Mn method bias and analytical imprecision. The techniques used included graphite furnace atomic absorption spectrometry (GFAAS), dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS), and sector field (SF-) ICP-MS. We analyzed NIST SRM 1643e Trace Elements in Water and SRM 1598a Inorganic Constituents in Animal Serum (both certified for Mn), and SRM 955c Toxic Metals in Caprine Blood - Level 1 (not certified for Mn). Various matrix effects in ICP-MS produced inaccurate results for SRM 1643e and discrepant results for SRM 955c. In the absence of a certified value for Mn in SRM 955c, we assigned a "consensus" value by combining data from the New York State Department of Health (NYS), the Centers for Disease Control and Prevention (CDC) and the Centre de toxicologie du Québec (CTQ). With this interlaboratory approach, we established an "all-lab" consensus value of 16.3 ± 0.8 μg L| based on data from DRC-ICP-MS with simple dilution sample preparation and blood-based calibration. We also assigned an "all-method" consensus value of 16.3 ± 0.9 μg L| based on GFAAS and SF-ICP-MS data from the NYS lab and the DRC-ICP-MS all-lab consensus value. Although the expanded uncertainty (|) calculated for the consensus values may not fully account for all sources of uncertainty, it does show the relative variation that might be expected from one study to the next for the determination of Mn in blood.
-
Subjects:
-
Source:J Anal At Spectrom. 27(11):1975-1982
-
Pubmed ID:26290619
-
Pubmed Central ID:PMC4539298
-
Document Type:
-
Funding:
-
Volume:27
-
Issue:11
-
Collection(s):
-
Main Document Checksum:urn:sha-512:495b095c8b4335e211a19f9d7b04c92fd37dcf4091dc2e8b8f4fe4066bf634765832bb695586c29cfa1315f05e1a71e96066f3abbdba8fcb0d0c3872ab748806
-
Download URL:
-
File Type:
Supporting Files
File Language:
English
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like
COLLECTION
CDC Public Access