An LC-MS/MS method for serum methylmalonic acid suitable for monitoring vitamin B12 status in population surveys1
Supporting Files
-
4 2015 ; 4-2015
-
Available in CDC Stacks on 2016-04-01T00:00:00Z
File Language:
English
Details
-
Alternative Title:Anal Bioanal Chem
-
Personal Author:
-
Description:Methylmalonic acid (MMA), a functional indicator of vitamin B12 insufficiency, was measured in the US population in the National Health and Nutrition Examination Survey (NHANES) from 1999 to 2004 using a GC/MS procedure that required 275 μL of sample and had a low throughput (36 samples/run). Our objective was to introduce a more efficient yet highly accurate LC-MS/MS method for NHANES 2011-2014. We adapted the sample preparation with some modifications from a published isotope-dilution LC-MS/MS procedure. The procedure utilized liquid-liquid extraction and generation of MMA dibutyl ester. Reversed-phase chromatography with isocratic elution allowed baseline resolution of MMA from its naturally occurring structural isomer succinic acid within 4.5 min. Our new method afforded an increased throughput (≤160 samples/run) and measured serum MMA with high sensitivity (LOD = 22.1 nmol/L) in only 75 μL of sample. Mean (±SD) recovery of MMA spiked into serum (2 d, 4 levels, 2 replicates each) was 94 % ± 5.5 %. Total imprecision (41 d, 2 replicates each) for three serum quality control pools was 4.9 %-7.9 % (97.1-548 nmol/L). The LC-MS/MS method showed excellent correlation (n = 326, r = 0.99) and no bias (Deming regression, Bland-Altman analysis) compared to the previous GC/MS method. Both methods produced virtually identical mean (±SD) MMA concentrations LC-MS/MS: 18.47 ± 0.71 ng/mL (n = 17), GC/MS: 18.18 ± 0.67 ng/mL (n = 11) on a future plasma reference material compared with a GC/MS method procedure from the National Institute of Standards and Technology 18.41 ± 0.70 ng/mL (n = 15). No adjustment will be necessary to compare previous (1999-2004) to future (2011-2014) NHANES MMA data.
-
Keywords:
- MMA
- method comparison
- GC/MS
- anticoagulant types
- NHANES
- NIST SRM 1950
- vitamin B12
- Anticoagulants
- Calibration
- Chromatography, Liquid
- Chromatography, Reverse-Phase
- Gas Chromatography-Mass Spectrometry
- Humans
- Liquid-Liquid Extraction
- Methylmalonic Acid
- Nutrition Surveys
- Quality Control
- Reference Standards
- Reproducibility of Results
- Sensitivity and Specificity
- Succinic Acid
- Tandem Mass Spectrometry
- Vitamin B 12
-
Source:Anal Bioanal Chem. 407(11):2955-2964
-
Pubmed ID:25258283
-
Pubmed Central ID:PMC4515767
-
Document Type:
-
Funding:
-
Volume:407
-
Issue:11
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:e38a359383c139121310207989d5282b4d579f7fe6cd831ec42c0e8d155d4365
Supporting Files
File Language:
English
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like
COLLECTION
CDC Public Access