Comparison of Clot-based, Chromogenic, and Fluorescence Assays for Measurement of Factor VIII Inhibitors in the U.S. Hemophilia Inhibitor Research Study
Supporting Files
-
7 2013 ; 7-2013
-
Available in CDC Stacks on 2015-06-23T00:00:00Z
File Language:
English
Details
-
Alternative Title:J Thromb Haemost
-
Personal Author:
-
Corporate Authors:
-
Description:Background ; Detection and validation of inhibitors (antibodies) to hemophilia treatment products are important for clinical care, evaluation of product safety, and assessment of population trends. ; Methods ; Centralized monitoring for factor VIII (FVIII) inhibitors was conducted for patients in the Hemophilia Inhibitor Research Study using a previously reported modified Nijmegen-Bethesda clotting assay (NBA), a chromogenic Bethesda assay (CBA), and a novel fluorescence immunoassay (FLI). ; Results ; NBA and CBA were performed on 1005 specimens and FLI on 272 specimens. CBA was negative on 880/883 specimens (99.7%) with Nijmegen-Bethesda units (NBU)<0.5 and positive on 42/42 specimens (100%) with NBU≥2.0 and 43/80 specimens (53.8%) with NBU 0.5–1.9. Among specimens with positive NBA and negative CBA, 58.1% were FLI-negative, 12.9% had evidence of lupus anticoagulant, and 35.5% had non-time-dependent inhibition. CBA and FLI were positive on 72.4% and 100% of 1.0–1.9 NBU specimens and 43.1% and 50.0% of 0.5–0.9 NBU specimens. FLI detected antibodies in 98.0% of CBA-positive and 81.6% of NBA-positive specimens (P=0.004). Among 21 new inhibitors detected by NBA, 5 (23.8%) with 0.7–1.3 NBU did not react in CBA or FLI. Among previously positive patients with 0.5–1.9 NBU, 7/25 (28%) were not CBA or FLI positive. FLI was positive on 36/169 NBU-negative specimens (21.3%). ; Conclusions ; FVIII specificity could not be demonstrated by CBA or FLI for 26% of inhibitors of 0.5–1.9 NBU; such results must be interpreted with caution. Low titer inhibitors detected in clot-based assays should always be repeated, with consideration given to evaluating their reactivity with FVIII using more specific assays.
-
Subjects:
- Adolescent
- Adult
- Autoantibodies
- Biomarkers
- Blood Coagulation
- Blood Coagulation Tests
- Child
- Child, Preschool
- Chromogenic Compounds
- Factor VIII
- Fluoroimmunoassay
- Hemophilia A
- Hemophilia B
- Humans
- Infant
- Linear Models
- Male
- Middle Aged
- Predictive Value of Tests
- Prospective Studies
- Reproducibility of Results
- Spectrophotometry
- United States
-
Keywords:
-
Source:J Thromb Haemost. 11(7):1300-1309
-
Pubmed ID:23601690
-
Pubmed Central ID:PMC4477744
-
Document Type:
-
Funding:
-
Volume:11
-
Issue:7
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:5e149ffc937bc976965f534081301015d47f3f1fa3caa682d7c8274d2972e734
Supporting Files
File Language:
English
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings, journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like
COLLECTION
CDC Public Access