A customized system for whole-body vibration measurement.

File Language:
English


Public Access Version Available on: May 29, 2027, 12:00 AM
Please check back on the date listed above.

Details

  • Alternative Title:
    Journal of Occupational and Environmental Hygiene, May 2026: A customized system for whole-body vibration measurement.
  • Journal Article:
    Journal of Occupational and Environmental Hygiene
  • Personal Author:
  • Description:
    This manuscript describes the technical components and performance of a custom whole-body vibration (WBV) instrumentation system designed for autonomous, prolonged field measurement. The study demonstrated the technical readiness of the system's accelerometers. The system integrates a Teensy 4.1 microcontroller, triaxial microelectromechanical system accelerometers, force sensing resistors, global positioning system module, and microSD data storage. The accelerometers were validated against reference accelerometers commonly used in field-based WBV measurement using a motion simulator programmed with complex vibration input profiles specified in ISO 7096:2020

    for testing operator seat vibration in earth moving machinery. In the time domain, accelerometers in the custom WBV instrumentation system exhibited ≤ 2.21% error in root-mean-square (RMS) amplitude measurements and < 0.03 g sample-to-sample RMS deviation from the reference accelerometers. Frequency-domain analysis (1/3-octave band) suggested slight underestimation of signal power at low frequencies (≤10 Hz), but the differences were practically small at each 1/3-octave band. Ultimately, the system will enable WBV monitoring in settings in which operators are remote and/or the schedule of machine operation is variable (e.g., agriculture). Future work will focus on real-world validation and exploring use of the force sensing resistors to characterize operator posture, further enhancing the system's utility in occupational WBV exposure monitoring.
  • Content Notes:
    Author manuscript
  • Keywords:
  • Source:
    Journal of Occupational and Environmental Hygiene, May 2026
  • DOI:
  • ISSN:
    1545-9624 ; 1545-9632
  • Pubmed ID:
    42214087
  • Pubmed Central ID:
    PMC13317734
  • Document Type:
  • Funding:
  • Genre:
  • Pages in Document:
    1-11
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:e9c9e6636b0d83b20f12379b23de2dca58d07c53b15ae0ff6b090f1077588dd891aa6dbfcb7c675ac0973582b077bfae2d01daff2dfa59632edba3eadd9801cf
File Language:
English
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.