U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Field Survey Report: Exposure Assessment of Peracetic Acid-Based Disinfectant Chemicals in a Hospital During Terminal Room Cleaning [2025-DFSE-2033]

Public Domain
File Language:
English


Details

  • Personal Author:
  • Description:
    Background: Peracetic acid (PAA) is a chemical with growing use as a disinfectant, sterilant, and biocide. PAA, in a mixture with hydrogen peroxide (HP) and acetic acid (AA), is used in a wide variety of industrial sectors including the food and beverage industry, feed, animal housing, hospitals and healthcare, agriculture, water purification, wastewater and sewage treatment, textile bleaching, pharmaceuticals, oil and gas, laundry, cosmetics, and the chemical industry. PAA is a strong oxidant with higher oxidizing potential than other biocides and is highly reactive on contact with organic material. PAA is corrosive to the skin, mucous membranes, and respiratory tract; and it is a sensory irritant. Although opportunities for employee exposures are increasing, there is little published information on workplace exposures or appropriate risk management approaches for working with mixtures of PAA, HP, and AA. Scientists from the National Institute for Occupational Safety and Health (NIOSH) are conducting a study to assess worker exposures to PAA-based disinfectants in healthcare, including hospitals. This report describes exposures to environmental services (EVS) staff at a hospital that uses a PAA-based disinfectant during discharge (or terminal) room cleanings. Assessment: A team of NIOSH researchers conducted a site visit to assess worker exposures to the components of a PAA-based disinfectant during room cleaning tasks. EVS staff were monitored for exposure to PAA, HP and AA while conducting discharge (or terminal) room cleanings. These cleanings are performed when patients are discharged or moved to another room and prior to the room being re-occupied. These cleaning procedures help reduce the likelihood of illness causing germs and bacteria from being spread from one patient to the next. During terminal room cleanings, EVS staff use the PAA-based disinfectant to clean and disinfect all low and high touch surfaces, including beds, bed rails, intravenous (IV) poles, tray tables, chairs, telephones, light switches, bathroom sinks and toilets as well as any other surface within the room. We collected 29 task-based air samples for HP, PAA, and AA on EVS staff performing discharge room cleaning activities. Each task was comprised of a discharge room cleaning and sample duration ranging from 8 to 37 minutes. We observed EVS staff while they performed their regular cleaning duties and noted task duration, cleaning product use, and use of any personal protective equipment. Results: Acetic Acid: Worker personal air samples for AA ranged from 0.15 to 1.26 parts per million (ppm) across the two days of sampling. NIOSH and the American Conference of Governmental Industrial Hygienists (ACGIH®) have a short-term exposure limit (STEL) of 15 ppm. The STEL is a 15-minute Time Weighted Average (TWA) exposure that should not be exceeded at any time during a workday. Peracetic Acid: Worker personal air samples for peracetic acid ranged from 0.04 to 0.50 ppm across the two days of sampling. ACGIH has a STEL of 0.4 ppm for peracetic acid. The Occupational Safety and Health Administration (OSHA) and NIOSH do not have a STEL for PAA. Hydrogen Peroxide: Worker personal air samples for HP ranged from Not Detected (ND) to 0.85 ppm across the two days of sampling. ACGIH, OSHA and NIOSH do not have a STEL for HP. ACGIH, OSHA and NIOSH have a full shift time weighted average limit of 1 ppm for HP, although it is not applicable to these short-term samples. Conclusions and Recommendations: All measured levels of acetic acid were below workplace safety limits for short term exposures. Four of the 29 short term sample results for PAA exceeded the ACGIH TLV-STEL of 0.4 ppm. There is no applicable short term OEL for HP. We observed varying levels of the disinfectant in the cloth buckets, including many with standing levels of disinfectant and rags which were dripping with the disinfectant when removed from the bucket for use. Several workers mentioned that the use of the chemicals caused tearing of the eyes and upper respiratory symptoms like runny or stuffy nose. We recommend that management ensure that employees understand potential hazards in the workplace and how to protect themselves. We also recommend that management ensure that employees have access and are informed of potential hazards and trained on the associated safe practices per the information found in the cleaning products' Safety Data Sheets (SDS). Specifically, employees should be educated on the documented health risks from exposure to HP, AA and PAA, as well as chemicals found in other cleaners at the hospital. We recommend that management work with employees to reinforce training on the proper use of disinfectant and other products used in discharge room cleanings. Discuss the amount of product that should be used in buckets containing the wetted cloths and help address the thought that "more is better." Further, we recommend that management require employees to wear extended cuff nitrile gloves or other compatible impervious gloves when using the disinfectant to minimize likelihood of skin exposure and irritation. Description provided by NIOSH
  • Subjects:
  • Keywords:
  • Source:
    Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, EPHB Report No. 2025-DFSE-2033, 2025 Apr; :1-24
  • DOI:
    10.26616/NIOSHEPHB2025DFSE2033
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    25 pdf pages
  • NIOSHTIC Number:
    nn:20071683
  • CAS Registry Number:
  • Federal Fiscal Year:
    2025
  • NORA Priority Area:
  • Peer Reviewed:
    False
  • Download URL:
  • File Type:
    Filetype[PDF - 358.78 KB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:0b5da7d587d4f1953b0662196b81ddb4afc3fec791404f46a03dff5fa876226ffdb1ddad276ad582ce524493fc73a5938d707a41fdbcc655b8a32d9c5ac319dd
File Language:
English
ON THIS PAGE
 Was this page helpful?
 Found an issue?
Send us an email at:
CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.