Serious Injury Report Report Slides F2025-01: Senior Captain and Two Firefighters of Ladder Company Burned During Primary Search in Garden Apartment Fire - Texas
Public Domain
-
2026/03/01
Details
-
Journal Article:National Institute for Occupational Safety and Health
-
Corporate Authors:
-
Description:On January 7, 2025, a senior captain and two firefighters were injured while performing a primary search in a garden apartment building. At 05:28 hours, the office of emergency communications (OEC) received the first call reporting an apartment fire and subsequently dispatched the first alarm assignment. District Chief 46 (DC46) arrived on scene with smoke showing in the courtyard. DC46 pulled past Side Alpha to view Side Charlie where fire had self-ventilated through a window. DC46 positioned across the street from the apartment complex facing the courtyard of the building and provided a size up of "District 46 on scene, fire showing on a two-story apartment, establishing command." DC46 updated Engine 35 (E35) that the fire appeared to be on the first floor past the courtyard (see Photo 1). E35 stretched a crosslay and an apartment lay preconnect from the rear of the engine. With the hoseline stretched to the front door of the apartment, E35A called E35D to charge the line repeatedly. Getting no response, E35A headed toward the engine and became involved in a physical altercation with a civilian. This prevented E35A from following Ladder 46's (L46) crew with a hoseline as they made entry into the apartment to conduct a primary search. The altercation between the civilian and E35 continued and subsequently distracted many of the personnel on scene. The door and living room window to the apartment were open with fire venting out when L46 made entry. Fire conditions progressed rapidly while L46's crew was inside conducting the primary search. During the civilian altercation with E35, flames filled the doorway and the door closed to the unit. DC46 requested a status update from E35 asking if there was water on the fire at 05:37 hours. E35A said they had water on the fire and were making entry. Less than a minute later E35A requested a medic unit to the front door. Immediately following that request was a Mayday call from L46B using the emergency activation button on the remote speaker mic. At the same time, firefighters from E35 attempted to force the door open and remove the L46 crew. L46A and L46C were removed rapidly once the door was broken down and removed. L46B self-extricated through the Side Alpha door about one minute after the other members of L46. At 05:41 hours, DC46 began conducting personnel accountability reports (PARs) for operating crews to account for all firefighters and requested a second alarm. Roughly a minute later, the L46 crew showed all in alert on the electronic accountability system. DC46 requested confirmation that all personnel were out of the structure. DC26 arrived on scene at 05:43 hours and assigned Side Alpha as their area of responsibility. Crews began re-entering the structure and extinguished the fire. At 05:44 hours, OEC updated command that 10 minutes had passed. At 05:55 hours, DC46 declared the incident under control. At 06:02 hours, DC46 updated OEC that three injured firefighters were transported from the scene. Contributing Factors: Fire behavior, dynamics, and tactics; Department culture and risk management; Impact of the personal protective equipment (PPE) on perception and recognition of environmental changes; Delayed water application and responder scene safety; Communication of conditions; Delayed fire department notification. Key Recommendations - Fire departments should: 1) Ensure firefighters employ tactics aligned with fire conditions when making entry to reduce thermal exposure to PPE. 2) Ensure personnel identify isolation opportunities from changing fire conditions. 3) Ensure all personnel are trained on the "GRAB LIVES" fireground survival techniques. 4) Develop a department culture that balances the life safety mission with proactive risk management. 5) Ensure that firefighters understand the capabilities and limitations of selected PPE for the applicable hazards and tactical operations. 6) Coordinate response procedures with local law enforcement to protect firefighters and prevent interference when working at emergency scenes. 7) Ensure incident commanders (ICs) immediately establish divisions/groups with a supervisor to communicate conditions, actions, or needs. 8) Ensure firefighters protect radios and cables by wearing radio straps under their turnout coat. 9) Educate the community to enhance individual knowledge, attitudes, and behaviors to help reduce risks, injuries, and fires within the community.
-
Subjects:
-
Keywords:
-
FACE - Firefighter:
-
Source:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE F2025-01, 2026 Mar; :1-14
-
Series:
-
Subseries:
-
DOI:10.26616/NIOSHFFFACEF202501RS
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:14 pdf pages
-
NIOSHTIC Number:nn:20071188
-
Federal Fiscal Year:2026
-
NORA Priority Area:
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:20250107
-
Collection(s):
-
Main Document Checksum:urn:sha-512:02894f3fd84b5ffe10b6f4a8aebe84079a32b1f8cfc454e68aec6467af6fdb51585232dcfd558abf8ed195b93febb514044ddff2bd99f4a53a8224edf77186b3
-
Download URL:
-
File Type:
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.