A field-portable colorimetric method for the measurement of peracetic acid vapors: a comparison of glass and plastic impingers (dataset).
Dataset
Public Domain
-
2022/07/13
File Language:
English
Details
-
Corporate Authors:
-
Description:A method for measuring PAA vapors in air using impinger sampling and field-portable colorimetric analysis is presented. The capture efficiency of aqueous media in glass and plastic impingers was evaluated when used for PAA vapor sampling. Measurement of PAA was done using a N,N-diethyl-p-phenylenediamine (DPD) colorimetric method with a field portable spectrometer. The linearity of the DPD method was determined for PAA both in-solution and captured from vapor phase using glass or plastic impingers. The Limit of Detection (LOD) for the glass and plastic impinger (0.24 mg/m3 (0.077 mg/L) and 0.28 mg/m3 (0.091 mg/L)), respectively, and Limit of Quantitation (LOQ) (0.79 mg/m3 (0.25 mg/L) and 0.92 mg/m3 (0.30 mg/L) for the glass and plastic impingers, respectively, are below the threshold limit value (TLV) short term exposure limit (STEL) of 1.24 mg/m3 (0.4 ppm) over a 15 minute period. This impinger method allows for a low cost, easy to use, and rapid in-field measurement for occupational exposure to PAA. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
DOI:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
NIOSHTIC Number:nn:20065557
-
Citation:Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Research Dataset RD-1041-2022-0, 2022 Jul; :dataset
-
Contact Point Address:Chemical and Biological Monitoring Branch (CBMB), Health Effects Lab Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Cincinnati, OH. Phone: 513-841-4428
-
CAS Registry Number:
-
Federal Fiscal Year:2022
-
NORA Priority Area:
-
Peer Reviewed:False
-
Source Full Name:A field-portable colorimetric method for the measurement of peracetic acid vapors: a comparison of glass and plastic impingers
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d6c22a0172b95fa8c413c036b1fb77da87522465ec0604f09d6be18563a98a820cb2d2192bd946ee97b93684d60b005b2ac73f11040adfda68756e209b2557ec
-
Download URL:
-
File Type:
File Language:
English
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like