Dosimetry for non-ionizing radiation.
-
1981/03/01
-
By Fanslow GE
-
Series: Grant Final Reports
Details
-
Personal Author:
-
Description:Several commercially available phosphor-teflon dosimeters were subjected to thermal fade studies. The thermoluminescence dosimetry (TLD) tags were washed in a detergent solution, rinsed in distilled water and then in alcohol, and air dried prior to each ionizing radiation pretreatment. Readings made over 3 weeks on the CaF2:Mn and CaF2:Dy TLD tags did not produce measurable thermal fade characteristics for the 22 to 31 degree-C temperature range. Nonionizing radiation treatments were at 2.45 gigahertz. While the results obtained did demonstrate decreases in signal levels over time and temperature changes, the patterns were not smooth, making it impossible to establish differences in TLD readings as quantitative measures of temperature differences which could serve as measures of long term exposures to nonionizing radiation. Directional and isotropic sensors were used to gather thermal response characteristics. When the TLD tags were attached to the sensors, the radiation test results produced similar fade patterns but smaller TLD signal differences. The authors concluded that, due to the irregularities that existed in the thermal fade characteristics, the dosimeter would not be suitable for quantifying exposures to nonionizing radiation. There was significant potential in the device, however, as an indicator of radiation leakage or exposure. [Description provided by NIOSH]
-
Content Notes:in NTRL, no pdf
-
Subjects:
-
Keywords:
-
Series:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-28
-
NIOSHTIC Number:nn:00181026
-
NTIS Accession Number:PB88247788
-
Citation:Department of Electrical Engineering, Iowa State University, Ames, Iowa, Terminal Progress Report, 1981 Mar; :1-28
-
Contact Point Address:Electrical Engineering Iowa State University College of Engineering Ames, Iowa 50011
-
Federal Fiscal Year:1981
-
Performing Organization:Iowa State University of Science & Tech, Ames, Iowa
-
Peer Reviewed:False
-
Start Date:19790928
-
Source Full Name:Department of Electrical Engineering, Iowa State University, Ames, Iowa, Terminal Progress Report
-
End Date:19801231
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like