Development of a method for the sampling and analysis of organotin compounds.
-
1982/04/01
-
Details
-
Personal Author:
-
Description:A technique for sampling and analysis of organotin compounds was developed and tested. Samples were collected on a glass fiber filter/XAD-2 resin system and were then extracted with 0.1 percent by volume acetic-acid in acetonitrile. Separation of organotin species prior to measurement was accomplished using high performance liquid chromatography (HPLC) with a strong cation exchange column. The test compounds were measured using an electrothermal atomization atomic absorption spectrometer connected directly to the HPLC. Atomization was accomplished on a zirconium coated graphite tube furnace. Recovery and collection/recovery tests were performed using tetrabutyltin (1461252) (TBT), tributyltin-chloride (1461229), and tricyclohexyltin-hydroxide (13121705). These compounds were chosen as representative of the classes of organotins most important with regard to health effects or production/use volumes. Recovery tests were performed by spiking glass fiber filters and XAD-2 resin with and then extracting, separating, and measuring the compounds. Aerosols and vapors of the test compounds with the same concentration range were generated using a nebulizer system. The compounds were collected with collection systems composed of glass fiber filters and XAD-2 solvent resin tubes connected in series. Samples were extracted, separated, and measured. All recovery values exceeded 95 percent except for TBT at 0.01mg/m3 which exceeded 90 percent recovery. All collection/recovery values exceeded 90 percent. Overall method precision was 10.8 percent for TBT, 6.0 percent for tributyltin-chloride, and 6.6 percent for tricyclohexyltin-hydroxide in the 0.05 to 0.2mg/m3 concentration range. Filter samples were stable under refrigeration or freezing for up to 7 days after collection. The authors conclude that the method meets NIOSH criteria for collection/recovery efficiencies and precision over the 0.05 to 0.2mg/m3 concentration range for the test compounds. [Description provided by NIOSH]
-
Content Notes:in NTRL, no PDF
-
Subjects:
-
Keywords:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-137
-
NIOSHTIC Number:nn:00135706
-
NTIS Accession Number:PB83180737
-
Citation:NIOSH 1982 Apr; :1-137
-
CAS Registry Number:
-
Federal Fiscal Year:1982
-
Peer Reviewed:False
-
Source Full Name:Division of Physical Sciences and Engineering, NIOSH, U.S. Department of Health and Human Services, Cincinnati, Ohio, NTIS PB83-180-737
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like