Sick building syndrome in a federal facility in Maryland.
Public Domain
-
1990/01/11
Details
-
Personal Author:
-
Description:An investigation of an outbreak of building related symptoms at a Federal facility was conducted. The investigation was prompted by a report of a possible epidemic of respiratory illness in employees in a ten story office building in a Federal facility located in a Maryland suburb of Washington, DC. A number of employees had complained of burning eyes, headache, chronic fatigue, and other symptoms since 1977. Previous investigations had found no agent that could have caused the symptoms, but had detected molds in the basement, and had documented inadequate performance of one of two heating, ventilation, and air conditioning (HVAC) units serving the building. A total of 423 employees in the building (building-A) and a nearby similar building (building-B) completed a questionnaire to obtain information on demographic characteristics, building exposure history, symptoms and prior medical history, smoking, and family history of respiratory illness. The HVAC systems in building-A were inspected. Environmental monitoring for carbon-dioxide (124389), hydrocarbons, pesticides, and other agents was performed at both buildings. Fifty five employees in building-A (17.4%) and eight at building-B (8.5%) were defined as cases; they reported experiencing three of the symptoms: running nose, headache, fatigue, and eye irritation for at least 30 days during the preceding year. Female workers in building-A were more likely to be cases than males. Smokers and workers older than 30 in building-A were less likely to be cases than nonsmokers and younger workers. Workers at building-A who reported respiratory allergies were more likely to be case than similar workers in building-B. Multivariate analysis indicated that being female and working in building-A were risk factors for being a case. Both HVAC units at building-A were operating, but pooling of condensate from the air was observed on the floors of air handling rooms for both units. Indoor and outdoor carbon-dioxide concentrations were similar at both buildings. The authors conclude that the incidence of respiratory symptoms is significantly associated with working in building-A independent of other risk factors. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Pages in Document:1-13
-
NIOSHTIC Number:nn:00205418
-
Citation:Atlanta, GA: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control, Field Epidemiology Report 90-05, 1990 Jan; :1-13
-
CAS Registry Number:
-
Federal Fiscal Year:1990
-
Peer Reviewed:False
-
Source Full Name:Sick building syndrome in a federal facility in Maryland
-
Collection(s):
-
Main Document Checksum:urn:sha-512:7dc847c09aedf140bc731323e8446b4703641ae07d6ad9e7b7238120dab30b8f7dcaa9b938d34d035f87873a0fe7fec262d5d13dcaf290925445e82b6de3b57d
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like