Evaluation of Fluid Leakage at the Coverall and Glove Interface in Single and Double Glove Conditions
Public Domain
-
2023/10/01
Details
-
Personal Author:
-
Description:Background: Fluid leakage through the glove-protective clothing interface is an area of concern for many healthcare personnel, including emergency medical service providers, who may wear coveralls to protect themselves from multiple types of hazards. There is currently no established standard test method to specifically evaluate the barrier performance of the glove-protective clothing interface region for any personal protective equipment ensemble. Objective: This study quantifies the fluid leakage at the coverall and glove interface using single and double gloving. Methods: A robotic arm, which can simulate upper extremity movements of healthcare personnel, was used to test five coverall models and an extended examination glove model in single and double glove conditions. Results: The results show that there was a significant difference in fluid leakage amounts between some of the coverall models and the number of glove layers studied. Findings also highlight that there is a high correlation between basis weight and stiffness of the coverall fabrics and the fluid leakage amounts. Conclusions: These results underline that coverall constructed from thin and less stiff fabrics can result in lower fluid leakage levels. Also, there was no significant difference in fluid leakage amounts between single and double gloves when tested with each of the coverall models, with the exception of the coveralls with the highest basis weight and stiffness. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0196-6553
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:51
-
Issue:10
-
NIOSHTIC Number:nn:20067146
-
Citation:Am J Infect Control 2023 Oct; 51(10):1145-1150
-
Contact Point Address:F. Selcen Kilinc-Balci PhD, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, 626 Cochrans Mill Road, Pittsburgh, PA 15236, USA
-
Email:jcq8@cdc.gov
-
Federal Fiscal Year:2024
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:American Journal of Infection Control
-
Collection(s):
-
Main Document Checksum:urn:sha-512:b1a519c844c5917a94d83da7cf69e3dc98bca54acf940eed1bce339b9e1f4c43ad38466e120a331c1c1082c6a8f9ac2827f438c8ded782b4e5ae8c8b594278d7
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like