U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Ambient and Laboratory Evaluation of a Low-Cost Particulate Matter Sensor



Details

  • Personal Author:
  • Description:
    Low-cost, light-scattering-based particulate matter (PM) sensors are becoming more widely available and are being increasingly deployed in ambient and indoor environments because of their low cost and ability to provide high spatial and temporal resolution PM information. Researchers have begun to evaluate some of these sensors under laboratory and environmental conditions. In this study, a low-cost, particulate matter sensor (Plantower PMS 1003/3003) used by a community air-quality network is evaluated in a controlled wind-tunnel environment and in the ambient environment during several winter-time, cold-pool events that are associated with high ambient levels of PM. In the wind-tunnel, the PMS sensor performance is compared to two research-grade, light-scattering instruments, and in the ambient tests, the sensor performance is compared to two federal equivalent (one tapered element oscillating microbalance and one beta attenuation monitor) and gravimetric federal reference methods (FEMs/FRMs) as well as one research-grade instrument (GRIMM). The PMS sensor response correlates well with research-grade instruments in the wind-tunnel tests, and its response is linear over the concentration range tested (200-850 µg/m3). In the ambient tests, this PM sensor correlates better with gravimetric methods than previous studies with correlation coefficients of 0.88. However additional measurements under a variety of ambient conditions are needed. Although the PMS sensor correlated as well as the research-grade instrument to the FRM/FEMs in ambient conditions, its response varies with particle properties to a much greater degree than the research-grade instrument. In addition, the PMS sensors overestimate ambient PM concentrations and begin to exhibit a non-linear response when PM2.5 concentrations exceed 40 µg/m3. These results have important implications for communicating results from low-cost sensor networks, and they highlight the importance of using an appropriate correction factor for the target environmental conditions if the user wants to compare the results to FEM/FRMs. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0269-7491
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    10 pdf pages
  • Volume:
    221
  • NIOSHTIC Number:
    nn:20067306
  • Citation:
    Environ Pollut 2017 Feb; 221:491-500
  • Contact Point Address:
    K.E. Kelly, University of Utah, Department of Chemical Engineering, 3290 MEB, 50 S. Central Campus Dr., Salt Lake City, UT, United States
  • Email:
    kerry.kelly@utah.edu
  • Federal Fiscal Year:
    2017
  • Performing Organization:
    University of Utah
  • Peer Reviewed:
    True
  • Start Date:
    20050701
  • Source Full Name:
    Environmental Pollution
  • End Date:
    20280630
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:a9732dde107affecc0acadaafcc8eedd9bc6bd3c8007b86d7e78aa85c8fd963365cf740e5ce1d9b2f91c3c1830cb8fdea9bc24c8a56914b8c6af65cb7d07f783
  • Download URL:
  • File Type:
    Filetype[PDF - 2.23 MB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.