U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Effect of Skin Protectants on the Total Inward Leakage of N95 Respirators: Testing with an Advanced Static Headform



Details

  • Personal Author:
  • Description:
    The COVID-19 pandemic introduced considerable challenges for respiratory protection of different population groups. Disposable medical masks and NIOSH-approved N95 filtering facepiece respirators (FFRs) are typically their only defense against the virus. At the same time, continuous wearing of these devices, especially some N95 FFR models cause damage to the facial skin, such as skin irritation, swelling, and scaling. Skin protectants are becoming increasingly popular and effective in providing a protective barrier for the skin that reduces direct contact between a wearer's face and respirator. Recent pilot studies involving human subjects have examined the effect of skin protectants on the performance of respirators/masks through fit testing, but their findings are heavily impacted by between-subject variability. This investigation deployed a standardized protocol that utilized the NIOSH advanced static manikin headform connected to a Breathing Recording and Simulation System (BRSS), producing a predetermined breathing pattern. The effect of skin protectants on the total inward leakage (TIL) was evaluated for three N95 FFR models, five different skin protectants, and two breathing flow rates. The aerosol particle concentrations inside and outside the respirator were measured with NaCl serving as the challenge aerosol. The TIL was shown to be significantly affected by the interaction of the skin protectant type, breathing flow rate and FFR models. The data suggest that different skin protectants may influence the performance of disposable N95 FFRs in different ways - by either increasing or decreasing the TIL value relative to one with no skin protectants applied. No negative effects on the TIL was observed for either tape- or gel/cream-type protectants when testing with 3M 8210 or 3M 1870+ FFRs; however, the use of skin protectants of either group with the AOSafety 1050 FFR may compromise its performance as quantified by the TIL. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    1680-8584
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Volume:
    22
  • Issue:
    7
  • NIOSHTIC Number:
    nn:20067889
  • Citation:
    Aerosol Air Qual Res 2022 Jul; 22(7):220175
  • Contact Point Address:
    Sergey A. Grinshpun, Center for Health-Related Aerosol Studies, Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, OH 45267-0056, USA
  • Email:
    sergey.grinshpun@uc.edu
  • Federal Fiscal Year:
    2022
  • Performing Organization:
    University of Cincinnati
  • Peer Reviewed:
    True
  • Start Date:
    20050701
  • Source Full Name:
    Aerosol and Air Quality Research
  • End Date:
    20260630
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:8031d33737b3a17d83ca9575c8cb399b1c93e9fb4d3906b639b084258486233012825dd560ebd79880a058f0fdd76cac1b790ae36fce32dfbaaf398c8ede1194
  • Download URL:
  • File Type:
    Filetype[PDF - 892.87 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.