Calibration of the Cloud and Aerosol Spectrometer for Coal Dust Composition and Morphology
Public Domain
-
2019/09/01
-
-
Series: Mining Publications
Details
-
Personal Author:
-
Description:The cloud and aerosol spectrometer (CAS) was calibrated to enable CAS sizing of coal dust for studies on flammable dust control. Coal dust sizes were determined by light-scattering theories for irregular particles that account for particle composition and morphology in computing coal dust diameters. Coal dust size computations were compared with test dust that was generated by cyclone separation and air-jet sieving and characterized by aerodynamic particle sizer (APS) and computer-controlled scanning electron microscopy (CCSEM) measurements. For test dust in the range of 0.5-32 µm, coal dust size distributions were consistent with cyclone-separated and sieve-segregated sizes. For the 3-20 µm size range, the coal dust size distribution had a mass median diameter that was 14% larger than that of the APS. This difference was reasonable considering that the basic calibration for glass spheres had 13% uncertainty. For the 20-32 µm and 32-45 µm test dusts, mass median diameters differed from CCSEM measurements by only 4% and 5%, respectively. Overall, the results suggest agreement between test dust sizes and computations for coal dust. Alternatively, using conventional Mie theory computations for spheres, coal dust mass median diameters were 35% and 40% larger than APS and CCSEM measurements, respectively. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Series:
-
ISSN:0921-8831
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:30
-
Issue:9
-
NIOSHTIC Number:nn:20056258
-
Citation:Adv Powder Technol 2019 Sep; 30(9):1805-1814
-
Contact Point Address:T.L. Barone, Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 626 Cochrans Mill Road, Pittsburgh, PA 15236, United States
-
Email:tbarone@cdc.gov
-
Federal Fiscal Year:2019
-
Peer Reviewed:True
-
Source Full Name:Advanced Powder Technology
-
Collection(s):
-
Main Document Checksum:urn:sha-512:027507d2e6d42282fae53faef11e80a88261ff3b5a9359e2c02c6ab71509bb515600c9cb377ac3f01ff7da3dcc8b2d79c27437855a0b2623ae77114482124c75
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like