Description:The United States National Institute for Occupational Safety and Health, through an informal partnership with industry, labor, and the United States Mine Safety and Health Administration, has developed and tested a new instrument known as the Personal Dust Monitor (PDM). The new dust monitor is an integral part of the cap lamp that coal miners normally carry to work and provides continuous information about the concentration of respirable coal mine dust within the breathing zone of that individual. Previous laboratory testing demonstrated that there is a 95% confidence that greater than 95% of individual PDM measurements fall within +/- 25% of reference measurements. The work presented in this paper focuses on the relationship between the PDM and respirable dust concentrations currently measured by a coal mine dust personal sampler unit utilizing a 10 mm Dorr-Oliver nylon cyclone. The United Kingdom Mining Research Establishment instrument, used as the basis for coal mine respirable dust standards, had been designed specifically to match the United Kingdom British Medical Research Council (BMRC) criterion. The personal sampler is used with a 1.38 multiplier to convert readings to the BMRC criterion. A stratified random sampling design incorporating a proportionate allocation strategy was used to select a sample of mechanized mining units representative of all US underground coal mines. A sample of 180 mechanized mining units was chosen, representing approximately 20% of the mechanized mining units in production at the time the sample was selected. A total of 129 valid PDM/personal sampler dust sample sets were obtained. A weighted linear regression analysis of this data base shows that, in comparison with the personal sampler, the PDM requires a mass equivalency conversion multiplier of 1.05 [95% C.I. = (1.03, 1.08)] when the small intercept term is removed from the analysis. Removal of the intercept term results in a personal sampler-equivalent concentration increase of 2.9% at a PDM measurement of 2.0 mg m(-3). [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Series:
-
ISSN:1464-0325
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:96-101
-
Volume:10
-
Issue:1
-
NIOSHTIC Number:nn:20033402
-
Citation:J Environ Monit 2008 Jan; 10(1):96-101
-
Contact Point Address:Steven J. Page, US Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, NIOSH, Pittsburgh Research Laboratory, 626 Cochrans Mill Road, Pittsburgh, PA 15236
-
Federal Fiscal Year:2008
-
Peer Reviewed:True
-
Source Full Name:Journal of Environmental Monitoring
-
Collection(s):
-
Main Document Checksum:urn:sha-512:61712c86ea9bd54f7961dacf5f8e1e5e1c37c6912dcf0f60d9405f30be1aab4ec6b3e3521f8d193eb0f0d43e79daa4c2f046f18296c769bad9e8c438081230da
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like