Effect of Keyboard Keyswitch Design on Finger Muscle Activity During Tapping on Isolated Keyswitches



Details

  • Personal Author:
  • Description:
    Aims: Intensive computer keyboard use is associated with hand and forearm musculoskeletal pain. The design of the keyswitch may play a fundamental role since the fingertip ultimately interfaces with the input device through the keyswitch. Previous studies have shown that finger kinematics and dynamics vary across keyswitch designs during tapping, however, these studies did not examine the specific relationship between keyswitch designs and intrinsic/extrinsic finger muscle activity. Therefore, this study aims to measure and characterize the index finger muscle activity patterns while tapping across isolated keyswitches of varying force-displacement characteristics. Methods: In a repeated-measures laboratory experiment, six subjects (3 females, 3 males) tapped with their right index fingers on three isolated keyswitches (1 buckling-spring, 2 rubber-dome) of varying force-displacement characteristics (Table 1) extracted from PC and Apple keyboards. Intramuscular (finewire) electromyography (EMG) provided a measure of muscle activity for the intrinsic muscles of the first lumbrical (LUM) and first dorsal interossei (FOi), and extrinsic muscles of the flexor digitorum profundus (FOP), flexor digitorum superficialis (FDS), and extensor digitorum communis (EDC). Muscle activity was characterized in terms of both magnitude (RMS EMG normalized to the highest EMG signal) and duration (time between onset and offset of muscle activity relative to initial keyswitch contact). Differences in EMG magnitude and duration across keyswitch design were analyzed using mixed effects analysis of variation models (Proc Mixed in SAS). Results: EMG magnitude and duration for both intrinsic and extrinsic muscles varied across keyswitch design (Figure 1; p<0.01). The keyswitch with the highest switch activation force and smallest key travel (Dome 2) was significantly associated with higher EMG magnitude for both intrinsic and extrinsic muscles, and only extrinsic muscles for EMG duration (p<0.01). Between the designs of similar keyswitch characteristics (i.e., Spring and Dome 1), the differences in both intrinsic and extrinsic muscle activity patterns were not statistically significant. Conclusions: Our findings indicate that tapping on keyswitch designs with lower activation forces, regardless of the switch mechanism (i.e., buckling-spring vs. rubber dome) reduces finger muscle activity patterns. Implications for these findings include the design of future keyswitches to reduce the exposure to risk factors that contribute to development of upper extremity musculoskeletal pain associated with intensive keyboard use. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • Publisher:
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    42
  • NIOSHTIC Number:
    nn:20060533
  • Citation:
    Sixth International Scientific Conference on Prevention of Work-Related Musculoskeletal Disorders (PREMUS 2007), August 27-30, 2007 Boston, Massachusetts. Rome, Italy: International Commission on Occupational Health (ICOH), 2007 Aug; :42
  • Federal Fiscal Year:
    2007
  • Performing Organization:
    Harvard University School of Public Health
  • Peer Reviewed:
    False
  • Start Date:
    20070301
  • Source Full Name:
    Sixth International Scientific Conference on Prevention of Work-Related Musculoskeletal Disorders (PREMUS 2007), August 27-30, 2007 Boston, Massachusetts
  • End Date:
    20120228
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:145526b23c7374583c4907f13a2c4ee38d045a993f0a348e8cb4d6f0f42cc4c1a81df25682f9bdaba9a4f77de6574990cba851d805abdde3ec3f3fa1e97a6605
  • Download URL:
  • File Type:
    Filetype[PDF - 684.69 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.