Flame Retardants, Dioxins, and Furans in Air and on Firefighters’ Protective Ensembles During Controlled Residential Firefighting
Public Domain
-
2020/07/01
-
Details
-
Personal Author:
-
Description:Introduction: Structure fires that involve modern furnishings may emit brominated flame retardants (BFRs) and organophosphate flame retardants (OPFRs), as well as brominated and chlorinated dioxins and furans, into the environment. Objectives: The goal of this study was to quantify the airborne and personal protective equipment (PPE) contamination levels of these compounds during controlled residential fires in the U.S., and to evaluate gross-decontamination measures. Methods: Bulk-sampling was done to confirm the presence of flame retardants (FRs) in the furnishings used in 12 controlled residential structure fires. Area air samples were collected during the fires and PPE wipe samples were collected from the firefighters' turnout jackets and gloves after firefighting. For each fire, half of the jackets were decontaminated and the other half were not. Results: Of the BFRs and OPFRs measured in air during the fire period, decabromodiphenyl ether (BDE-209) and triphenyl phosphate (TPP) were the most abundant, with medians of 15.6 and 408 micro g/m3, respectively, and were also detected during overhaul. These and several other BFRs and OPFRs were measured on PPE. Some gloves had contaminant levels exceeding 100 ng/cm2 and were generally more contaminated than jackets. Air and surface levels of the brominated furans appeared to be higher than the chlorinated dioxins and furans. Routine gross decontamination appeared to reduce many of the BFR contaminants, but results for the OPFRs were mixed. Conclusions: Structure fires are likely to result in a variety of FRs, dioxins, and furans into the environment, leading to PPE contamination for those working on the fireground. Firefighters should wear self-contained breathing apparatus during all phases of the response and launder or decontaminate their PPE (including gloves) after fire events. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:0160-4120
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Volume:140
-
NIOSHTIC Number:nn:20059804
-
Citation:Environ Int 2020 Jul; 140:105756
-
Contact Point Address:Kenneth W. Fent, Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, 1090 Tusculum Ave, MS R-14, Cincinnati, OH 45226
-
Email:kfent@cdc.gov
-
CAS Registry Number:
-
Federal Fiscal Year:2020
-
NORA Priority Area:
-
Peer Reviewed:True
-
Source Full Name:Environmental International
-
Collection(s):
-
Main Document Checksum:urn:sha-512:34c8c464996c043b96101fb2a091c07b9c789970795f0d376efc70d72d5a9e5641fdf0972663139119c40f154a603717df4736d3995294134eaf61bae20ad11a
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like