Ammonia Exposure and Hazard Assessment for Selected Household Cleaning Product Uses
-
2005/11/01
-
Details
-
Personal Author:
-
Description:There is scant information pertaining to airborne ammonia exposures from either spills or common household uses of ammonia-containing floor and tile cleaners or from spray-on glass cleaners. We assessed instantaneous and event-specific time-weighted average (TWA) exposures to airborne ammonia during spills and use (per label directions) of a household floor and tile cleaner and two spray-on window cleaners. Airborne ammonia levels measured at breathing zone height (BZH) above the spilled floor and tile cleaner product reached 500 p.p.m. within 5 min, while levels for spilled window cleaner were below 8 p.p.m. TWA exposures were assessed while tile walls and floors were cleaned in three different bathrooms of a residence, and during use of a spray-on glass cleaner while washing several large windows in an office setting. NIOSH Method 6015 was utilized with concurrent field measurements every 60 s using a Drager PAC III monitor with an electrochemical cell detector. Peak ammonia levels ranged from 16 to 28 p.p.m. and short-term TWA concentrations ranged from 9.4 to 13 p.p.m. during mixing (0.1% ammonia) and cleaning tiles in the three bathrooms. Ammonia exposures while using spray-on window cleaner were over 10-fold lower (TWA=0.65 p.p.m.). Use of the floor and tile cleaner mixed at 0.2% ammonia led to peak airborne ammonia levels within 3-5 min at 36-90 p.p.m., and use of full strength cleaner (3% ammonia) led to peak ammonia levels of 125 to >200 p.p.m. within 2-3 min. Spillage or intentional use of the full strength floor and tile cleaner led to airborne ammonia concentrations that exceed occupational short-term exposure limits, while spillage or use of the spray-on window cleaner did not approach potentially hazardous airborne ammonia levels and likely represents a minimal inhalation health hazard. We conclude that routine household uses of ammonia are unlikely to produce significant exposures when using standard cleaning solutions (0.1-0.2%), but spillage or use of concentrated ammonia solutions (e.g., 3%) in poorly ventilated areas can lead to potentially hazardous airborne ammonia exposures. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
ISSN:1053-4245
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Topic:
-
Location:
-
Volume:15
-
Issue:6
-
NIOSHTIC Number:nn:20058430
-
Citation:J Expo Anal Environ Epidemiol 2005 Nov; 15(6):534-544
-
Contact Point Address:Dr. Brent D. Kerger, 2976 Wellington Circle West, Tallahassee, FL 32309, USA
-
Email:brentkerger@att.net
-
CAS Registry Number:
-
Federal Fiscal Year:2006
-
Performing Organization:University of California Los Angeles
-
Peer Reviewed:True
-
Start Date:20050701
-
Source Full Name:Journal of Exposure Analysis and Environmental Epidemiology
-
End Date:20270630
-
Collection(s):
-
Main Document Checksum:urn:sha-512:32d1ed35a0ce64ab9123305072bdb04e7a6827bfc499a7b87b000163784321b571bdd0efe080774ba59314f17972111d18b10485d3bed9d2040ae236f9411402
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like