Permeation of Telone EC (TM) Through Protective Gloves



Details

  • Personal Author:
  • Description:
    Telone is a potent fumigant that is based on the chlorinated unsaturated hydrocarbon, 1,3-dichloropropene (1,3-DCP). It is often applied without dilution and so poses severe inhalation and air pollution threats. Urinary metabolites of 1,3-DCP have been detected after Telone skin exposure, so that preventing dermal exposure is also important. The objective of the study was to assess if nitrile and multi-layer ("laminated") gloves provide adequate protection against Telone EC(TM) formulation. To accomplish this, disposable (Safeskin(TM)) and chemically resistant (Sol-Vex(TM)) nitrile and laminated (Barrier(TM) and Silver Shield(TM)) glove materials were challenged by Telone EC(TM) with hexane liquid collection in an ASTM-type I-PTC-600 permeation cell. Analyses of cis- and trans-1,3-DCP in the collection fluid at specified times were performed on a moderately polar capillary column by gas chromatography-electron capture detection. Telone EC(TM) caused microholes in both nitrile materials, though the chemically protective material was degraded slower than the disposable nitrile. The laminated gloves offered limited protection. Silver Shield(TM) protected best because 1.5-2.3 mg 1,3-DCP permeated by 8 h relative to 2.5-7.6 mg for Barrier(TM), implying about 2.5 times more protection for 8 h. Even for Silver Shield(TM), the extent of protection was inadequate as illustrated by a risk assessment of the skin exposure situation. The normalized breakthrough times for both types of laminated gloves varied between 27 and 60 min. It is recommended that Viton gloves still be worn for protection. [Description provided by NIOSH]
  • Subjects:
  • Keywords:
  • ISSN:
    0304-3894
  • Document Type:
  • Funding:
  • Genre:
  • Place as Subject:
  • CIO:
  • Topic:
  • Location:
  • Pages in Document:
    81-87
  • Volume:
    124
  • Issue:
    1
  • NIOSHTIC Number:
    nn:20058387
  • Citation:
    J Hazard Mater 2005 Sep; 124(1-3):81-87
  • Contact Point Address:
    Shane S. Que Hee, Department of Environmental Health Sciences and UCLA Center for Occupational and Environmental Health, School of Public Health, University of California at Los Angeles, 650 Charles Young Jr. Drive South, Los Angeles, CA 90095-1772, USA
  • Email:
    squehee@ucla.edu
  • Federal Fiscal Year:
    2005
  • Performing Organization:
    University of California Los Angeles
  • Peer Reviewed:
    True
  • Start Date:
    20000601
  • Source Full Name:
    Journal of Hazardous Materials
  • End Date:
    20040531
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:86c534434df8491ac47c8787afc82e83c6f24f82b31edadf56f55c705a99baa53dc3e633cddb4ccfa3fa429c1b8448059a57bc92f64ee0cdc68d67867cdf1f44
  • Download URL:
  • File Type:
    Filetype[PDF - 83.54 KB ]
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.