Infrared Thermography Identifies Laser Ignition Thresholds
Public Domain
-
2000/02/01
-
Series: Mining Publications
Details
-
Personal Author:
-
Description:The National Institute for Occupational Safety and Health (NIOSH) Pittsburgh Research Laboratory (PRL) are conducting research to provide a scientific basis for developing appropriate safety guidelines for optical equipment in the presence of flammables to determine laser ignition thresholds for methane-air mixtures and/or coal dust. Researchers from NIOSH-PRL are working with safety standards committees such as: The International Society for Measurement and Control (ISA) and the International Electrotechnical Committee to develop safety recommendations for lasers in hazardous locations. In phase 1 of the "Laser Safety for Hazardous Locations" project, infrared thermographs recorded temperatures of iron oxide particles on optical fiber tips heated by laser powers that previously have produced methane-air ignition. About 120 experiments were conducted to determine laser-heated target temperatures at and near laser powers required to ignite methane-air, under several different test conditions producing temperatures in the range of 1300 to 1500 Celsius. The research is part of a project to recommend safe power limits for lasers used in coal mines. In one phase of the project, researchers used a thermal imaging system which measured infrared radiation at wavelengths of 3.6 to 5um, and was calibrated up to 1500 degrees C by the manufacturer. A 30/BO-mm close-up lens allowed very high spatial resolution. Prior to observations of the optical fibers, the temperature calibration and spatial resolution of the thermal imaging system were confirmed by using small apertures placed in front of a blackbody source. Temperature measurements were within manufacturer's specifications down to the smallest aperture, a' 340-um hole drilled through a thin metal sheet. In phase II of the project the infrared system recorded time lapse thermographic images of a laser beam incident on a coal dust layer. The thermal imaging system measures infrared radiation at wavelengths from 3.6 to 5 micrometers (micro m). The manufacturer calibrated the system to accurately measure temperatures up to 1500 Celsius (Degrees C) for the high temperature tests. The calibration of the system was confirmed here at PRL with a blackbody source. Of particular interest in our research is the use of this system to provide continuous quantitative analysis of thermal runaway phenomenon. The system is used to observe spatial and temporal temperature variations of a coal hot spot. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Series:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-2
-
Volume:15
-
NIOSHTIC Number:nn:20020759
-
Citation:Infrared News Break 2000 Feb; 15(Feb):1-2
-
Email:wdm2@cdc.gov
-
CAS Registry Number:
-
Federal Fiscal Year:2000
-
Peer Reviewed:False
-
Source Full Name:Infrared News Break
-
Collection(s):
-
Main Document Checksum:urn:sha-512:4c64cb885bb117026e62c630865198d6e9f9c09871c288cce68d7b99f0b8e9fb2ccb058ef2e29db84f493feb0a40af2f436f5646d5dfc7f7ce539bbc278fe613
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like