Ventilation Control to Reduce Airborne Contaminants
-
2002/03/21
-
-
Series: Grant Final Reports
Details
-
Personal Author:
-
Description:Studies have shown conclusively that airborne contaminant levels in swine confinements are typically of a sufficient level to pose a health hazard to workers in that occupation. In addition to a particulate component that can reach levels of 26 mg/m3, gases present in confinements in high amounts include methane, hydrogen sulfide, ammonia, and carbon dioxide. Recognized respiratory diseases of swine farmers include upper airway inflammation, an asthma-like syndrome, and chronic airflow limitations. Ventilation systems associated with swine confinements are largely designed to provide a comfortable climate for the pigs. However, because confinements are operated on a for-profit basis, costs associated with operating the ventilation system are typically kept to a minimum by minimizing fan usage, which results in maintaining high airborne contaminant levels. This research involved the analysis of continuous readings of two environmental parameters, temperature and relative humidity, and two air quality parameters, airborne dust and ammonia, relative to measurements taken by standard sampling methods. Results indicated a relatively good correlation between the real-time temperature and humidity recordings and standard sampling methods but low correlation between sensor-based dust and ammonia measurements and those taken by standard method. Therefore, the use of these monitors as direct-reading instruments for feedback control of airflow rates to mitigate concentration levels is suspect. Robust sensors that are easily calibrated and capable of withstanding the harsh environment of a swine confinement are needed. To simulate the effect of airflow on environmental and quality control parameters, computer software capable of simulating dynamic processes was utilized. The resulting model output was compared and validated with the real-time measurements taken on site with results showing a close agreement between the two. Development of models ofthis sort show promise in accurately determining the effect of ventilation through a room or building on the resulting indoor air quality expressed in terms of environmental conditions or airborne hazards. [Description provided by NIOSH]
-
Subjects:
-
Keywords:
-
Series:
-
Document Type:
-
Funding:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-10
-
NIOSHTIC Number:nn:20023514
-
NTIS Accession Number:PB2003-107713
-
Citation:NIOSH 2002 Mar; :1-10
-
CAS Registry Number:
-
Federal Fiscal Year:2002
-
NORA Priority Area:
-
Performing Organization:Department of Occupational and Environmental Health, Institute for Rural and Environmental Health,The University of Iowa, Iowa City, Iowa 52242
-
Peer Reviewed:False
-
Start Date:19990401
-
Source Full Name:National Institute for Occupational Safety and Health
-
End Date:20020331
-
Collection(s):
-
Main Document Checksum:urn:sha-512:e22cda6fd3768af16f2373513936a7be2cc822cca9dca2e6cafd0cf409c6a1feb7955b61325d1ed8c33fe49589b17a851901d2d6583bf4b9f314c44a31b5e85a
-
Download URL:
-
File Type:
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like